166
SmartStack STS16-20D/STS16-20R Token Ring Switches Installation and User Guide
Monitoring the Network from the Console Statistics Menu
Ring Number Mismatch
Indicates the number of times that an incoming frame did not correctly include the
port’s ring number. That is, the ring number of the port must be the last, if it is an
explorer frame. Note that the switch performs a ring number test when the topology
of the network changes. At that time the port might be disabled.
Config Loss
Number of configuration loss events after the port has completed the join process
and then lost communication.
Config Loss Reason
Latest Config Loss error code. Possible values are:
•
None
•
Wire Fault
- Wire fault.
•
Lobe Test
- Lobe test failure.
•
HDX in FDX
- HDX MAC frame received in FDX mode.
•
Heart Beat
- Heart beat failure.
•
FDX New Sta
- FDX new station.
•
Auto
-Disable reason.
Last Reset
Time since last reset of port statistics.