68
SmartStack STS16-20D/STS16-20R Token Ring Switches Installation and User Guide
Installation
Table 12. Inter-box Parameters
Checking the Installation
The SmartStack STS16-20D/STS16-20R performs a diagnostic self-test during the
power on cycle. From a management console, check that the switch lists the
SmartStack STS-LM port along with the switch ports and that there are no error
messages. The SmartStack STS-LM port will be listed as port 29.
If, after installation, there is poor system performance or the SmartStack STS-LM
module does not work at all, remove the module and check for any damaged or bent
connector pins. You may need a bright light to see inside the stacker slot to check
for bent pins. Also, verify that the module is set firmly in place.
❏
Menu
Parameter
IP Configuration
IP Address, IP Gateway, IP Subnet, IP State
Spanning Tree
Protocol
STP Enabling/Disabling, STP Switch Priority, STP
Maximum Aging, STP Hello Time, STP Forward Delay
Virtual LAN
Name
Configuration
Changing VLAN names
Password
System password
Console
Configuration
Console Time-out
Telnet
Configuration
Number of Allowed Telnet Sessions, Disallow New Telnet
Sessions
TFTP Download
TFTP Server Address, Download Domain, Download
Filename
Switch/Stack
Information
Stack Timeout, System Name, System Contact, System
Location
SNMP
Configuration
Send Authentication Traps, changing the Trap table in any
way, changing the Community Name table in any way
Summary of Contents for SmartStack STS16-20R
Page 1: ...SmartStack STS16 20D STS16 20R Token Ring Switches Installation and User Guide ...
Page 2: ......
Page 14: ...xii Notice ...
Page 256: ...index 6 SmartStack STS16 20D STS16 20R Token Ring Switches Installation and User Guide Index ...
Page 257: ......
Page 258: ... 710001812 ...