9W006 and 9W007 111
S
YSTEM
M
ESSAGES
System Message Summary
<timestamp> # 0000: Error reading platform type: there is no “plat name” field
There is no <platform name> value following the “=” character in the “current setting” string.
<timestamp> # 0000: Error reading platform type: there was no “=” in the string
The “current setting” string has the format “<platform type>=<string>”. This error message
indicates that no “=” character exists in the string.
<timestamp> # 0000: Error reading platform type: type value is too large
The <platform type> value in the “current setting” string is too large to represent an actual platform
type.
<timestamp> # 0000: Error reading platform type: type was not converted to an int
The <platform type> value in the “current setting” string could not be converted to an actual
platform type.
1 port LAN Adapter, operating in remote mode only
This is an initialization message. It identifies the Ethernet adapter type (Ethernet-1), and operating
mode. Remote bridging is supported.
2 port LAN Adapter, operating in local and remote mode
This is an initialization message. It identifies the Ethernet adapter type (Ethernet-2), and operating
mode. Both local and remote bridging are supported.
aarp found duplicate AppleTalk address <AppleTalk Address> @ <MAC address>
The address resolution protocol found duplicate AppleTalk addresses for this AppleTalk network.
Check the configuration for the AppleTalk ports’ network range/number.
Abnormal response rcvd: <state msg reason cc state>
An unexpected message was received from a WAN interface card. The <parameters> included are
for problem reporting purposes only. If the system fails to operate normally, or the warning
continues to occur, contact your Distributor or Customer Support.
A call has exceeded the configured maximum duration
A call has been up longer than the amount of time configured. The next log message will inform
the user whether or not the call has been taken down.
ACE authentication is not available. You must first ENABLE ACE user level authentication.
An attempt was made to configure the Terminal Server Security for ACE and ACE was not
configured on the SmartSwitch Remote Access Module.
Adapter does not respond: adapter # ’x’
The WAN card initialization subsystem encountered an error on the indicated adapter. Restart the
system. If the problem persists, the indicated adapter card may be faulty and you should contact
your Distributor or Customer Support.
Adapter # ’x’ failed to initialize
The operational software on the indicated adapter card failed to signal that initialization was
completed. Restart the system. If the problem persists, the indicated adapter card may be faulty and
you should contact your Distributor or Customer Support.