USER’S GUIDE
156 SmartSwitch Remote Access Module
SSB: Post 23 i960host_int_reg FAILURE
The i960 failed its internal register test. The boot process should continue; however, make note of
the error message in the event of a future problem.
SSB: Post 24 i960io_int_reg FAILURE
The i960 failed its I/O register test. The boot process should continue; however, make note of the
error message in the event of a future problem.
SSB: Post 25 i960io_mod_mem_1 FAILURE
The i960 failed its I/O memory test using the first test pattern. The boot process should continue;
however, make note of the error message in the event of a future problem.
SSB: Post 26 i960io_mod_mem_2 FAILURE
The i960 failed its I/O memory test using the second test pattern. The boot process should continue;
however, make note of the error message in the event of a future problem.
SSB: Post 27 i960timer_82c54FAILURE
The i960 failed its timer unit test. The boot process should continue; however, make note of the
error message in the event of a future problem.
SSB: Post 28 i960lan_82596sx FAILURE
The i960 failed its LAN Coprocessor test. The boot process should continue; however, make note of
the error message in the event of a future problem.
SSB: Post 29 i960lan_82503 FAILURE
The i960 failed its LAN transceiver test. The boot process should continue; however, make note of
the error message in the event of a future problem.
SSB: Post 30 i960per_mod_mem_1 FAILURE
The i960 failed its peripheral buffer memory test using the first test pattern. The boot process
should continue; however, make note of the error message in the event of a future problem.
SSB: Post 31 i960per_mod_mem_2 FAILURE
The i960 failed its peripheral buffer memory test using the second test pattern. The boot process
should continue; however, make note of the error message in the event of a future problem.
SSB: Post 32 i960hdlc_1 FAILURE
The i960 failed its 80532 test using the first HDLC controller. The boot process should continue;
however, make note of the error message in the event of a future problem.
SSB: Post 33 i960hdlc_2 FAILURE
The i960 failed its 80532 test using the second HDLC controller. The boot process should continue;
however, make note of the error message in the event of a future problem.
SSB: Post 34 i960hdlc_3 FAILURE
The i960 failed its 80532 test using the third HDLC controller. The boot process should continue;
however, make note of the error message in the event of a future problem.
SSB: Post 35 i960hdlc_4 FAILURE
The i960 failed its 80532 test using the fourth HDLC controller. The boot process should continue;
however, make note of the error message in the event of a future problem.