9W006 and 9W007 157
S
YSTEM
M
ESSAGES
System Message Summary
SSB: Post 36 i960isdn_1 FAILURE
SSB: Post 37 i960isdn_2 FAILURE
SSB: Post 38 i960isdn_3 FAILURE
SSB: Post 39 i960isdn_4 FAILURE
The i960 failed its 2086 test using the first (second, third or fourth) D-channel controller The boot
process should continue; however, make note of the error message in the event of a future problem.
SSB: Timed out waiting for i960 to initialize for POSTSs
The i960 did not respond to an initialization request in a timely manner. This is a i960 failure. The
boot process should continue; however, make note of the error message in the event of a future
problem.
Starting Triggered RIP/SAP for <device>
This message indicates that triggered RIP/SAP has started for a device (either locally configured
or one present in the WAN peer list). Triggered RIP/SAP has been configured as a routing protocol
for this particular device.
Stream Ready rejected - MTU too small
The remote device will only accept the stream connection if the MTU is set to be > 1514. Check to
make sure that the remote device and the SmartSwitch Remote Access Module MTU value is set to
> 1514.
[STP] A BLAN Topology Change has been detected
The system has detected a topology change in the Spanning Tree environment.
[STP] A new Root Bridge has been detected
The system has detected a new root bridge for the Spanning Tree environment.
[STP] LAN Port <port # > is now a Designated Port
The indicated LAN port has become the designated port for the attached LAN.
[STP] LAN Port <port # > is now the Root Port
The indicated LAN port has become the root port for the system.
[STP] This Bridge is now the Root Bridge
The system has become the root bridge for the Spanning Tree environment.
Successfully Loaded Release <X.Y> Issue <Z>
The specified release of System software was successfully loaded into memory.
Switch could not recognize phone number nnnnnnn
The switch did not accept the phone number dialed as a complete number. Check the correctness
of the phone number (including any leading digits such as 8 or 9).
System Clock Fault on Wan Adapter in Slot <slot # >
Indicates a TDM bus connection failure. Check to make sure that the TDM bus has been correctly
connected.
TACACS authentication is not available. You must first ENABLE TACACS user level authentication.
An attempt was made to configure the Terminal Server Security for TACACS and TACACS was
not configured on the SmartSwitch Remote Access Module.