3.3 Mains Input and Wiring
On the rear of the unit there is one IEC mains socket for connection to
an independent mains supply. The primary earth connection is made via
this socket.
WARNING - this appliance must be earthed.
VORSICHT - Nur eine vorschriftsmäßig geerdete Steckdose
anschließen.
A single mains cable is supplied with the SBU128, 2 metres in length
with an appropriate approved plug for the country concerned. This
should be connected to a suitable mains supply. The mains plug is the
primary disconnect device for the unit. Ensure that the unit is installed
near to a socket outlet and that the outlet is easily accessible.
N.B. The use of adaptors is not recommended and may invalidate
approval of the product.
The wires in the supply cord are coloured in accordance with the
following code:-
Green and Yellow
Earth
Blue
Neutral
Brown
Live
As these colours may not correspond with the terminations in the plug
being used, it should be connected as follows:-
The green and yellow wire must be connected to the terminal marked
with the letter E, or with the earth symbol, or coloured green, or coloured
green and yellow.
The blue wire must be connected to the terminal marked with the letter
N, or coloured black, or coloured blue.
The brown wire must be connected to the terminal marked with the letter
L, or coloured red, or coloured brown.
All data communications links to the unit should be in accordance with
the cable specifications given in this manual.
WARNING:
Summary of Contents for SmartSwitch SBU128
Page 3: ...SBU128 User Manual 80 10200000 01 iii History Sheet 80 10200000 01 V1 00 Software 31 July 1998...
Page 74: ...SBU128 User Manual 80 10200000 01 11 2 11 1 Configuration Menu...
Page 75: ...Command Maps 80 10200000 01 11 3...
Page 76: ...SBU128 User Manual 80 10200000 01 11 4 11 2 Operation Menu...