Configuration Commands
80-10200000-01
4–7
4.5.3 Alarm Port Menu
*) SPEED
*) ECHO
No selection is possible.
C) MODE
A) REMOTE
A) LOW PRIORITY
(F)
If all ‘B’ channels are
busy, the alarm call is
made when a ‘B’
channel is free.
B) HIGH PRIORITY
Alarm call is made
before the ‘B’ channel
is used for backing up
the User port.
D) FLOW
CONTROL
A) RTS/CTS (F)
RTS/CTS flow control is
effective.
B) XON/XOFF
DC1/DC3 inband flow control
is effective.
C) DISABLED
No flow control is used on the
Command Port.
E) ALERTS
A) SHORT
FORMAT
No time and date provided
with ALERTs.
B) LONG
FORMAT
Time and date stamp
provided with all ALERTs.
C) DISABLED (F)
No ALERTs presented.
F) QUEUE
LENGTH
This sets the length of the
queue required before an
alarm call is made.
G) FLUSH TIMER
This sets the time at which
stored ALERTs are deleted
H) CALL HOLD
TIME
This sets how long that the
ISDN call is maintained, after
transmitting the outstanding
ALERTS held in memory.