9
Earth Leakage
Protection
DC Leak (6ma)
DC Leak (6ma)
DC Leak (6ma)
DC Leak (6ma)
Start Charging
RFID Card
OCPP Control
APP Control
RFID Card
OCPP Control
APP Control
RFID Card
OCPP Control
APP Control
RFID Card
OCPP Control
APP Control
Indicator
LED Light belt (red, blue,
green)
Digital display
LED indicators
LED Light belt (red, blue,
green)
Digital display
LED indicators
LED Light belt (red, blue,
green)
Digital display
LED indicators
LED Light belt (red, blue,
green)
Digital display
LED indicators
Power Metering
Power meter
(MID certified)
Power meter
(MID certified)
Power meter
(MID certified)
Power meter
(MID certified)
Connectivity
Wifi(Client)/Wifi (AP)
Hotspot
RS485 (Power
management with
external meter)
CAN (Load balancing)
Wifi(Client)/Wifi (AP)
Hotspot
RS485 (Power
management with
external meter)
CAN (Load balancing)
Wifi(Client)/Wifi (AP)
Hotspot
RS485 (Power
management with
external meter)
CAN (Load balancing)
Wifi(Client)/Wifi (AP)
Hotspot
RS485 (Power
management with
external meter)
CAN (Load balancing)
Communication
Protocol
OCPP1.6J
OCPP1.6J
OCPP1.6J
OCPP1.6J
Background
Functions
WIFI system upgrade
WIFI system upgrade
WIFI system upgrade
WIFI system upgrade
Reports
Charge reports
Fault reports
Charge reports
Fault reports
Charge reports
Fault reports
Charge reports
Fault reports
Protection
Function
Overcurrent protection
Overvoltage protection
Undervoltage protection
Relay over temperature
protection;
Socket or plug over
temperature protection;
CP fault protection;
Relay adhesion
protection;
Overcurrent protection
Overvoltage protection
Undervoltage protection
Relay over temperature
protection;
Socket or plug over
temperature protection;
CP fault protection;
Relay adhesion
protection;
Overcurrent protection
Overvoltage protection
Undervoltage protection
Relay over temperature
protection;
Socket or plug over
temperature protection;
CP fault protection;
Relay adhesion
protection;
Overcurrent protection
Overvoltage protection
Undervoltage protection
Relay over temperature
protection;
Socket or plug over
temperature protection;
CP fault protection;
Relay adhesion
protection;
IP Degree
IP54
IP54
IP54
IP54
Ambient
Temperature
-25°C to +50°C
-25°C to +50°C
-25°C to +50°C
-25°C to +50°C
Operating
Humidity
≤95%RH
≤95%RH
≤95%RH
≤95%RH
Certificates
Standards
IEC 61851-1: 2017
(RED WiFi 2.4GHz----RF: EN 300 328 RF-EMC: EN 301 489-1&-17 Health (MPE): EN 62311)
(RED RFID 13.56MHz----RF: EN 300 330 RF-EMC: EN 301 489-1&-3 Health (MPE): EN 62311)
CE Certificates
CB from DEKRA/CE from DEKRA