20
Display
Area
Type
Function description
AREA3
Tap RFID card area prompt light
The four square corners of the RFID card tap area are highlighted
to show where the RFID card should be active
All
around
the
charger
LED indicator
A LED belt is placed all around the charger and assumes different
colours to indicate the current status (see table below)
LED Belt
Colour
Blinking mode
Status
White
No blinking
Power on self-test: the charger is switching on and performing the power on
tests
Green
Blinking slowly
Stand-By mode: the charger is on, available for charging
Blue
Fast blinking
Pause during the charging process
Blue
No blinking
Charging mode setup: the charger is preparing to start the charging process
Blue
Blinking slowly
Charging mode: the charging process is ongoing
Red
Error mode: errors are detected by the internal protections
7.1.2
Digital character display (AREA1)
The following table shows the format of the information presented by the frontal display:
Display string format
(Letter “c” = single character)
Unit
Description
ccc.0
V
Where ccc = Input supply voltage value (V)
cc.c
A
Where cc.c = Charging current value (A)
cc.c
Hz
Where cc.c = Input supply voltage frequency (Hz)
cc.c
kWH
Where cc.c = Output power (kWH)
ccc
Min
Where ccc = Charging process duration (Min)
These data are presented in rotation on the display.
In case of errors/faults/abnormal behaviours, the display can show the following error message
codes. The following table explains the meaning of each error code:
Display string format
Description
ERR OCP
Over-current fault
ERR OVP
Over-voltage fault
ERR LVP
Under-voltage fault
ERR MET
Meter communication fault
ERR PE
Ground fault
ERR CP
CP voltage fault
ERR R12
Relay 1 blocked fault
ERR R3N
Relay 2 blocked fault
ERR ROT
Relay over-temperature fault
ERR ELK
Electronic lock abnormal fault
ERR OCT
Plug holder over-temperature fault
ERR IRD
Leakage fault
ERR FAN
Fan fault (the fan is blocked)