OpERATING MODES

Your Steam Humidifier can be installed to operate on 120 volts, 208 volts 
or 240 volts using 11 .5 or 16 .0 amps . The higher the voltage and amperage 
the higher the potential output .

Amperage

Voltage

Maximum steam capacity (gal/day)

11 .5

120V

11 .5

208V

20 .5

240V

23 .3

16 .0

120V

16 .0

208V

30 .0

240V

34 .6

It may take several days for the humidifier to reach rated capacity 
depending on the input voltage and the electrical conductivity of 
the water. 

120 volt systems take longer to reach rated capacity than 240 

volt systems . The humidifier should always be plumbed to cold water but 
the water can be softened or unsoftened . “Hard” water, which has a high 
mineral content, and softened water generally has higher conductivity than 
naturally soft water . Systems plumbed to higher conductivity water will 
reach capacity sooner than systems plumbed to low conductivity water . As 
the humidifier operates, minerals build up in the canister, which increases 
the conductivity of the water . With a new canister, allowing the humidifier 
to operate continuously (along with the indoor unit blower) will allow it to 
reach rated capacity in the shortest amount of time .

INSTALLATION OpTIONS AND EFFECT OF  

WATER CHARACTERISTICS

When the humidifier is powered and turned on, the “On/Off” light is 
illuminated green .
When the canister is being filled or replenished with water, the “Fill” light 
illuminates green .
When the canister is being drained, the “Drain” light illuminates green .
During initial start up with a new canister, the humidifier may run through 
a series of fill/drain cycles until the conductivity of the water is in a range 
that allows normal operation . During this time, the “Steam” light illuminates 
green . If the humidifier cannot produce steam at the rated level after trying 
for 168 hours, the “Steam” light illuminates yellow . The humidifier continues 
to operate in this state until the rated output is reached .
The conductivity of naturally soft water, hard water, and softened water 
changes as the water heats up, but the internal controller adjusts the 
water level to maintain a nominal current between the electrodes . Over 
the life of the canister, minerals that build up on the electrodes will reduce 
their effective surface area and affect the resistance between them . The 
operating water level will increase with use until it reaches the high water 
level probe . At that point, the “Service” light will flash red indicating that 
the canister needs to be replaced . The humidifier will continue to operate 
but with reduced output .
When the humidifier begins a drain cycle, the fill valve opens to introduce 
cold water into the canister . This is done to prevent hot water from 
entering the drain . The drain valve remains open for four minutes to allow 
all water to drain from the canister . 
Any time power is disconnected or humidifier is turned off, the internal 
timer for start-up and drain cycles is reset .
If the humidifier has operated 168 hours without a drain cycle, the drain 
valve will open and drain the canister . Normal operation will continue .
If the humidifier is operating and a power failure occurs, once power 
is restored, the “On/Off” light will flash green for one minute, then the 
humidifier will turn on .

END OF SEASON/pERIOD OF INACTIVITy SHUT-DOWN

If the humidifier does not receive a call to operate in 72 hours, the 
humidifier controller drains the canister . The drain light will remain on until 
there is a humidity call or 24 hours has elapsed . The humidifier will resume 
normal operation when a call for humidity is made .

Summary of Contents for HUMXXSTM3034

Page 1: ...READ AND SAVE THESE INSTRUCTIONS Model HUMXXSTM3034 Residential Steam Humidifier Owner s Manual Includes Safety Operating Instructions Residential Steam Humidifier ...

Page 2: ... until electrical power is disconnected Follow the shutdown procedure in this manual before performing service or maintenance procedures on any part of the system Electrical shock hazard If the humidifier starts up responding to a call for humidity during maintenance severe bodily injury or death from electrical shock could occur Follow the procedures in this manual before performing service or ma...

Page 3: ...m and Canister 90 1522 Steam Outlet Drain Supply Water Drain Cup Drain Valve Canister Electrodes High Water Level Sensor Flow Control Orifice Inlet Fill Valve Overflow Fill Fill Cup Thank you for your recent steam humidifier purchase We appreciate your business and are pleased to add your name to our growing list of customers You have invested in the highest quality equipment available Your humidi...

Page 4: ...s time the Steam light illuminates green If the humidifier cannot produce steam at the rated level after trying for 168 hours the Steam light illuminates yellow The humidifier continues to operate in this state until the rated output is reached The conductivity of naturally soft water hard water and softened water changes as the water heats up but the internal controller adjusts the water level to...

Page 5: ...rent level below 75 of the maximum operating current Humidifier continues to operate but at reduced capacity Solid Red Operational problem with humidifier Humidifier shuts down Occurs when unit detects over current which can be caused by failure to drain or other system failures Call your heating and air conditioning dealer for service HUMIDIFIER CONTROL OPERATING INSTRUCTIONS The control provided...

Page 6: ...obe conductor 5 Loosen hose clamp at top of canister 6 Slide hose off top of canister 7 Slide canister up and out of drain assembly Discard canister 8 Remove o ring from drain assembly using small screw driver 9 Inspect drain assembly and remove any debris See drain valve cleaning procedure in Installation Maintenance manual 10 Insert new o ring into slot in drain assembly O ring is provided with ...

Page 7: ...Form OG HUMXXSTM 01 10009952 B2205831A 10 12 2012 CAC BDP 7310 West Morris St Indianapolis IN 46231 ...

Reviews: