Connecting the mixer systems
1-1
Revision B2005-2
B-Type
4
&RQQHFWLQJ
#
WKH
#
PL[HU
#
V\VWHPV
414
&RQVROH
#
PRGXODULW\
The B-Type features CADAC’s unique frame design which allow users to put any
module in any position, thus configuring the console to suit the project in hand. Each
module is fitted with XLR connectors and jack sockets on the rear vertical face,
enabling the module to be moved quickly and easily.
The B-Type module’s design features a motherboard, with plug-in daughter boards
for all audio and digital control functions. This ensures servicing simplicity and fast
replacement of any faulty component. Each module may be plugged into any posi-
tion in the console frame, by means of top quality two-part connector system, which
is designed as a mating pair to provide excellent mechanical and electrical reliability.
A rail system is used to guide each module into its correct position. Also, the console
design allows modules to be removed or inserted without powering down.
415
)UDPH
#
UHDU
#
FRQQHFWLRQV
The connections on the B-Type console rear frame include the following (from left to
right):
■
■
■
■
Audio Bus - frame to frame, up to 4 frames can be connected.
■
■
■
■
Data Bus - frame to frame
■
■
■
■
Frame selector
■
■
■
■
Comms to CCM
■
■
■
■
PFL output to next frame.
■
■
■
■
PFL input from module.
■
■
■
■
PSU1 connector
■
■
■
■
PSU2 connector
■
■
■
■
Output for monitoring of PSUs
■
■
■
■
GND - 0 - FRAME
■
■
■
■
Littlite input from PFL module.
■
■
■
■
Littlite output to next frame.
■
■
■
■
Littlite output to lights
■
■
■
■
Audio Bus
■
■
■
■
Data Bus
The use of these connectors is described in
1.3.5 Main and extension frame power
1.4 Connecting the console frames
and
.
6
7
4
5
6
7
4
5
AUDIO BUS
AUDIO BUS
HEADPHONES NEXT FRAME
GND - 0 - FRAME
PSU 1
PSU 2
5 AMP FAN FUSE
FRAME TO FRAME
FRAME TO FRAME
DATA BUS
DATA BUS
FRAME
SELECTOR
COMMS TO CCM
INPUT TO HEADPHONES JACK SOCKETS
FROM PFL NEXT LIGHTS
PSU INDICATOR
FIG 1-1. B-Type frame rear connections.
Summary of Contents for B-Type
Page 1: ...Audio Mixing Console 056 6 10 n 95 4 1 07 g8 2...
Page 6: ...vi General Precautions B Type Revision B2005 2...
Page 8: ...viii Introduction B Type Revision B2005 2...
Page 48: ...2 20 Central Control Module 7896 B Type Revision B2005 2...
Page 86: ...6 10 Group Module 7756 B Type Revision B2005 2...
Page 96: ...7 10 Grand Master Group module 7795 B Type Revision B2005 2...
Page 106: ...9 4 Auxiliary Output Module 7468 B Type Revision B2005 2...
Page 122: ...11 10 Osc Comms PFL module 7758 M Type groups B Type Revision B2005 2...
Page 130: ...12 8 Osc Comms PFL module 7635 F Type groups B Type Revision B2005 2...