1-2
Connecting the mixer systems
J-Type
Revision J2005-2
416
&RQQHFW
#
3RZHU
#
VXSSO\
#
V\VWHPV
41614
3RZHU
#
VXSSO\
#
V\VWHP
#
GHVFULSWLRQ
Cadac consoles are designed to allow the use of two independent power supply sys-
tems in a redundant configuration – “main” and “backup”. Both sets of power supply
units are used to power the console system so that under normal conditions, the
‘load’ is shared between the “main” and “backup” PSU’s. If a fault occurs in one of the
power units (causing it to ‘shut-down’), the remaining power unit will power the con-
sole.
For smaller J -Type consoles (consuming no more than 44A), it is possible to use the
8400 PSU. See 1.3.7 8400 Switch-Mode Power Supply Unit.
One ±18V PSU and one +13V/+48V PSU is referred to as a “PSU System”.
Designate one pair of power supply units as “SYSTEM 1" and the other as “SYSTEM
2". PSU System 1 and PSU System 2 should be connected to the same
phase and
on the same ‘spur’, wherever possible. In situations where it is necessary to provide
a separate ‘feed’ to each PSU system pair, make sure that the cable lengths are the
same. This is to minimize any induced a.c. power input noise by ensuring that the
“EARTH IMPEDANCE” is the same for both PSU systems.
/
1
(
/
1
(
/
1
(
/
1
(
-
-
-
-
$5($
#
%5$1&+
#
3$1(/
$5($
#
%5$1&+
#
3$1(/
$5($
#
%5$1&+
#
3$1(/
*1'
#
%$5
*1'
#
%$5
1
#
/
0$,1
#
*5281'
#
5()(5(1&(
#
($57+
#
(/(&752'(
#
6<67(0
FIG 1-2. AC mains grounding diagram (single phase 200-240V)
368
#4
$
368
#4
%
368
#5
$
368
#5
%
Summary of Contents for J-Type
Page 1: ...Audio Mixing Console 056 6 10 n 95 4 1 07 g8 2...
Page 4: ...iv Table of contents J Type Revision J2005 2...
Page 6: ...vi General Precautions Revision J2005 2 J Type...
Page 8: ...viii Introduction J Type Revision J2005 2...
Page 72: ...3 22 7496 Dual Input Channel J Type Revision J2005 2...
Page 86: ...3 36 7830 Dual input channel J Type Revision J2005 2...
Page 96: ...4 10 7925 Programmable Group Module J Type Revision J2005 2...
Page 102: ...4 16 7972 Programmable Aux Groups Module J Type Revision J2005 2...
Page 110: ...4 24 7548 Programmable Routing Slave Mod Mk II J Type Revision J2005 2...
Page 146: ...6 14 7106 Quad Panning module J Type Revision J2005 2...
Page 154: ...7 8 6910 Oscillator PFL Stereo Aux module J Type Revision J2005 2...
Page 188: ...8 16 7956 DC Master Motor fader J Type Revision J2005 2...
Page 200: ...INDEX 4 J Type Revision J2005 2 W Wiring the switches 1 6 X XLR connections APP I...