background image

� Connections  to the main power

and  the  electrical  system  must

comply  with  the  regulations  in 

force  in the  country  of installation of 

the  appliance;  and  all  connections 

must  be  performed  by  qualified 

personnel  authorised  by  Cadco. 

Failure  to  comply  with  these 

regulations  may  cause  damage  and 

injuries, invalidates the  warranty* and 

relieves Cadco of all liabilities. 

Before 

connecting  the  appliance  to the 

mains electricity, always  compare the 

power  supply  data  with  that  of the 

appliance  specified  on  the  rating 

plate.  The  appliance is  released  from 

the factory with power cable and plug 

already connected to the terminal. Do 

not  make any  other type  of electrical 

connection  and  no  dimensional 

modification  of  the  cable  other  than 

extensions,  replacing  it  only  with 

one  having  specifications  equal  to 

the  original  factory  cable  (type  of 

rummer, cross-section, etc.). 

�  The  cable  must  be  replaced  by 

�  Cadco  or  by  its 

technical 

assistance service, and in all 

cases by  a person  with similar 

qualification  in order to avoid possible 

risks. 

�  The  wiring  diagrams,  wire 

¥

specifications and the technical

data  are  indicated  on  the 

"Technical 

specifications" 

sheet 

attached to  the appliance. 

For proper electrical connections, the 

appliance must: 

Be  wired  into  an  equipotential 

system  in  accordance  with  current 

regulations.  This  connection  must 

be  performed  between  different 

appliances  with  the terminal  marked 

with  the  equipotential  symbol 

if) 

.  The  cable  must  have  a  maxim� 

crnss-section  of 10  mm2  (pursuant 

standard  CEI  EN  60335-2-42:2003-

09) and  be of yellow-green colour.

- Must  be  grounded  •  to  the

earthing (green-yellow�re).

- Must  be  connected  to  a  ther­

mal  differential  switch  in  compli­

ance  with  the  regulations  in  force

(0.03A  Type A).

- Must be  connected  to  a omni po­

lar circuit breaker mechanism that

enables  complete  disconnection

in category  Ill over voltage condi­

tions.

CHECKS 

- The  copper  jumper  in  the  termi­

nal  board  and  the  electrical  cable

must  be  secured  together  under

the  screw  in  its  tightening  direc­

tion;  and  the  electrical  connec­

tions  must  be  securely  tightened

before  connecting  the  appliance

to the electricity mains.

- Check  for  any  electrical  disper­

sion  between  the  phases  and  the

ground,  and  for  electrical  conti­

nuity  between the external  casing

and the main ground line.

- Check that the power supply volt­

age  does  not  deviate  from  the

nominal  voltage  value  specified

on the appliance rating plate when

the  appliance  is  operating.  If  this

is not the case,  wire the phases  as

specified on the "technical specifi­

cations" sheet attached.

l

it 

WARNING! 

Electrical Grounding Instructions: appliance is equipped with 

a three-prong (grounding) plug for your protection against shock hazard and 

should be plugged directly into a properly grounded three-prong receptacle. 

Do not cut or remove the grounding prong from this plug. 

25 

Summary of Contents for BAKERLUX SHOP.Pro XAKHT-HCHS

Page 1: ......

Page 2: ......

Page 3: ......

Page 4: ...IDE REPAIR SHOULDBE DONEBY AUTHORIZED SERVICE PERSONNEL ONLY GENERAL SAFETY Read this guide carefully before installing or maintain ing the appliance and conserve this guide with care for any future c...

Page 5: ...als and cor rectly disposed of in compliance with local regulations The ratings plate provides essential technical infor mation that is of utmost importance for any appliance maintenance or repairs Do...

Page 6: ...and water supplies and contact a Cadco au thorized customer assistance service Do not attempt to independently repair the appliance R equest Cadco original spare parts for any repairs necessary To en...

Page 7: ...nvalidates the warranty PICTOGRAMS The installation and user instructions are valid for all models unless otherwise specified by the following pictograms Danger Situation presenting immediate danger o...

Page 8: ...t exit the oven when the door is opened Table A COOKING TRAYS tffi I We recommend you thoroughly read for all instructions on how to maintain the aesthetic and functionaI qualities of your purchased p...

Page 9: ......

Page 10: ......

Page 11: ...d from the factory and must only be transported using pallets supplied by Cadco Each unit has been carefully inspected before it was packaged and consigned to a shipper installer Upon delivery Inspect...

Page 12: ......

Page 13: ...using pallet jacks I WARNING The packaging material is potentially dangerous It must be kept out of the reach of children and animals and correctly disposed of in compliance with local regulations ST...

Page 14: ...fied technicians in compliance with local state and federal regulations CHECKING PACKAGE CONTENTS BeforeinstaIIingthe applianee check that the following components are in the package and undamaged Con...

Page 15: ......

Page 16: ...Top oven flue model STEFANIA ARIANNA Bottom oven flue model STEFANIA ARIANNA 16 ft Make sure that you do not mix up the smoke flue connections and the condensation outlet OUT...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...ust pipe on the top portion of the appliance Where multiple ovens are stacked the bottom oven and the one those above must be connected to the hood To do this you must use the extension included in th...

Page 21: ......

Page 22: ......

Page 23: ...here are no W objects or materials obstructing the flue or which maybedamaged by thetemperature or fumes Do not leave flammable materials near the smoke exhausts 2 Evacuation through an efficient vent...

Page 24: ...correct connection can lead to personal injury or even electrocution Incorrect connection of the W electrical wires may damage the appliance O grey or white neutral wire black red blue phase L1 L2 L3...

Page 25: ...s connection must be performed between different appliances with the terminal marked with the equipotential symbol if The cable must have a maxim crnss section of 10 mm2 pursuant standard CEI EN 60335...

Page 26: ...comply with applicable federal state and local codes INLET WATER CHARACTERISTICS Any damage caused by using U water with parameters that do not correspond to what is specified in this section is not...

Page 27: ...drops of reagent Cadco Finest Cl 10 ppm 2 drops of reagent Reverse Osmosi System NHM 500 S cm Reverse Osmosi System use the reagent in the Cadco KSTR1081A kit hardness measured using the Cadco KSTR108...

Page 28: ...filter UNOX Finest O cold water supply thermally controlled by a temperature sensor IN 28 lPO liiii JID Plumbing connection to the left Jfliilii i 11il Plumbing connection to the ri ht itlUiiiiil J P...

Page 29: ......

Page 30: ...ns and the conden sation outlet OUT Top oven ELENA Bottom oven out Top oven ROSSELLA 0 f residual water discharge OUT 30 A It is recommended that the hood use a floor drain to discard the spent water...

Page 31: ......

Page 32: ......

Page 33: ......

Page 34: ......

Page 35: ......

Page 36: ...ggressive or corrosive deter gents e g hydrochloric muriatic or sulphuric acid abrasive or sharp tools abrasive sponges scrapers steel bristled brushes etc water jets EXTERNAL STEEL SURFACES Wait for...

Page 37: ......

Page 38: ......

Page 39: ...onnected to the hood _J Manufacturer s Information Cadco Ltd 200 International Way Winsted CT 06098 860 738 2500 lsmith cadco ltd com www cadco ltd com Possible cause ISolution The hood is not connect...

Page 40: ......

Reviews: