background image

INSTALLATION AND SETUP

Follow the steps described below to install and configure the system.

1) Install Security System
You must first install the security system; refer to the GE/CADDX documentation for details.

For the GE/Caddx NX-8, NX-6 or NX-4, you must also install an NX-584 serial interface board into the security system.
The NX-584 connects to the POS, GND, and DATA keypad
screw terminals on the GE/CADDX panel and provides the RS-232
serial interface (DB-9) that STARGATE connects to.
   NOTE: The NX-584 has four jumpers (J7, J8, J9, J10)
that control the functions of the DB-9 serial port pins.
Leave the NX-584 jumpers in their default positions.
Jumpers J7 & J10 toward DB-9 serial connector (J6),
Jumpers J8 & J9 away from DB-9 serial connector.

The GE/CADDX NX-8e has built-in serial communication and does not require a NX584. Instead, use a ZCIF232 interface
adaptor kit to provide a serial connection. (See connection diagram on page 1)

We strongly recommend you get the security system up and running before connecting it to STARGATE.
This will reduce the likelihood of problems and make troubleshooting much easier.

2) Configure Security System Communication Settings
The GE/CADDX security system provides a variety of configurable settings that control how it works. These must be properly
set up before it can be used with STARGATE.  The table below shows the required settings and the programming locations for
each. Refer to the GE/CADDX Installation Manual for further details on how to program these.
If your GE/CADDX security panel is set to its default settings, press * 8 9 7 1 3 7 2 # for NX-8/6/4 or * 8 9 7 1 3 0 # for NX-8e from
the Caddx keypad to begin programming.  Then continue programming the following settings.

Set to ASCII Mode

0

1

1 _ _ _ _ _ _ _

Set to 9600 baud

1

1

_ _ _ 4 _ _ _ _

Enable Transitions

2

1

_ _ _ _ _ 6 7 _

Command/Request Enables

3

1

_ 2 _ 4 5 6 7 8

Request functions

3

2

1 2 3 _ _ _ _ _

3

3

_ _ _ _ _ _ _ _

Enable keypad functions

3

4

_ _ 3 4 5 6 7 8

(none)

NX584 Enabled

207

1

1 _ _ _ _ _ _ _

Set to 9600 baud

208

1

_ 2 _ _ _ _ _ _

Set to ASCII Mode

209

1

1 _ _ _ _ _ _ _

Enable Transitions

210

1

_ _ _ _ _ 6 7 _

Command/Request Enables

211

1

_ 2 _ 4 5 6 7 8

Request functions

211

2

1 2 3 _ _ _ _ _

211

3

_ _ _ _ _ _ _ _

Enable keypad functions

211

4

_ _ 3 4 5 6 7 8

(none)

NX-8/6/4

NX-8e

NX-584

DB-9

LEDS

J8

J10

J7

J9

J6

To

STARGATE

To

GE/CADDX

Keypad

Terminals

POS
COM
DATA

REQUIRED SETTING

      Location

                   Segment

           Bits to turn ON

REQUIRED SETTING

      Location

                   Segment

           Bits to turn ON

Reviews: