13
LOCATION 103: PROGRAMMING TO REPORT OPENINGS
The Ranger 8000 has the ability to report an opening code each time the control is disarmed. The desired opening
code is programmed in location 103. If this location contains a "0", openings will not be reported. When using 4+2
format, the number programmed in this location is sent as the"tens" digit. The "ones" digit is automatically the man
number. When using the remote arming input, the man number is 1.
LOCATION 104-105: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 1
Locations 104-105 contain the communicator code to be reported each time zone 1 creates an alarm. Location 104
contains the standard digit, and location 105 contains the extended digit. When using 4+2 format, the number
programmed in location 104 is sent as the "ones" digit. The "tens" digit is programmed in location 105.
LOCATION 106-107: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 2
Locations 106-107 contain the communicator code to be reported each time zone 2 creates an alarm. Location 106
contains the standard digit, and location 107 contains the extended digit. When using 4+2 format, the number
programmed in location 106 is sent as the "ones" digit. The "tens" digit is programmed in location 107.
LOCATION 108-109: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 3
Locations 108-109 contain the communicator code to be reported each time zone 3 creates an alarm. Location 108
contains the standard digit, and location 109 contains the extended digit. When using 4+2 format, the number
programmed in location 108 is sent as the "ones" digit. The "tens" digit is programmed in location 109.
LOCATION 110-111: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 4
Locations 110-111 contain the communicator code to be reported each time zone 4 creates an alarm. Location 110
contains the standard digit, and location 111 contains the extended digit. When using 4+2 format, the number
programmed in location 110 is sent as the "ones" digit. The "tens" digit is programmed in location 111.
LOCATION 112-113: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 5
Locations 112-113 contain the communicator code to be reported each time zone 5 creates an alarm. Location 112
contains the standard digit, and location 113 contains the extended digit. When using 4+2 format, the number
programmed in location 112 is sent as the "ones" digit. The "tens" digit is programmed in location 113.
LOCATION 114-115: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 6
Locations 114-115 contain the communicator code to be reported each time zone 6 creates an alarm. Location 114
contains the standard digit, and location 115 contains the extended digit. When using 4+2 format, the number
programmed in location 114 is sent as the "ones" digit. The "tens" digit is programmed in location 115.
LOCATION 116-118: RESERVED
LOCATION 120-121: PROGRAMMING TO REPORT AC POWER LOSS
The Ranger 8000 has the ability to report an AC power failure code when AC power is lost. This report can be
immediate, or delayed depending on the information programmed in location 150 (AC Power Loss Delay). The desired
AC failure mode should be programmed in locations 120-121. If both locations are "0", AC power failures will not be
reported. Location 120 contains the standard digit, and location 121 contains the extended digit. When using 4+2
format, the number programmed in location 120 is sent as the "ones" digit. The "tens" digit is programmed in location
121.