10
TABLE 1.1
DATA
FORMAT
DESCRIPTION
"0"
LOCAL ONLY
THE COMMUNICATOR IS DISABLED
"1"
UNIVERSAL 4 + 2
1800HZ TRANSMIT 2300HZ HANDSHAKE DOUBLE ROUND
PARITY 20 PPS.
"2"
ADEMCO/SILENT KNIGHT FAST
1900HZ TRANSMIT 1400HZ HANDSHAKE DOUBLE ROUND
PARITY 20 PPS.
"3"
CADDX MODEM
PROPRIETARY
"4"
RESERVED RESERVED
"5"
EXTENDED RADIONICS SLOW
1800HZ TRANSMIT 2300HZ HANDSHAKE DOUBLE ROUND
PARITY 20 PPS EXTENDED HEX CAPABILITY
"6"
EXTENDED RADIONICS SLOW
1800HZ TRANSMIT 1400HZ HANDSHAKE DOUBLE ROUND
PARITY 20 PPS EXTENDED HEX CAPABILITY
"7"
EXTENDED RADIONICS FAST
1800HZ TRANSMIT 2300HZ HANDSHAKE DOUBLE ROUND
PARITY 40 PPS EXTENDED HEX CAPABILITY
"8"
EXTENDED RADIONICS FAST
1800HZ TRANSMIT 1400HZ HANDSHAKE DOUBLE ROUND
PARITY 40 PPS EXTENDED HEX CAPABILITY
"9"
EXTENDED RADIONICS FAST
WITH PARITY
1800HZ TRANSMIT 2300HZ HANDSHAKE SINGLE ROUND
W/PARITY 40 PPS EXTENDED HEX CAPABILITY
A="10"
EXTENDED RADIONICS FAST
WITH PARITY
1800HZ TRANSMIT 1400HZ HANDSHAKE SINGLE ROUND
W/PARITY 40 PPS EXTENDED HEX CAPABILITY
B="11"
ADEMCO 4 + 2 EXPRESS
DTMF
C="12"
SILENT KNIGHT 4 + 2
1900HZ TRANSMIT 1400 HANDSHAKE DOUBLE ROUND
20PPS
D="13"
ADEMCO CONTACT ID
DTMF (See Appendix 2)
E="14"
SIA
FSK (See Appendix 1)
F="15"
PAGER/CUSTOM FORMAT
SEE OVER-RIDE LOCATIONS 182, 183, 208, 209.
PROGRAMMING INSTRUCTIONS
LOCATIONS 000-003: PROGRAMMING THE MASTER ARM/DISARM CODE
Locations 000-003 contain master arm/disarm code (user number 1). Location 000 contains the first digit of the code;
location 003 contains the fourth digit of the code. THE CODE MUST CONTAIN FOUR (4) DIGITS. The master code can
then be used in the run mode to enter arm/disarm codes 1-7 as described on page 37, ENTERING AND CHANGING
THE MASTER CODE. The factory default code is [1][2][3][4]. NOTE: User codes 8 through 14 can only be accessed
from the installers programming level in locations 212-239.
LOCATIONS 004-023: PROGRAMMING THE ARM/DISARM CODE FOR USERS 2 THRU 6
Locations 004-023 contain the arm/disarm codes for user numbers 2 thru 6. Location 004 contains the first digit of the
code #2, and location 007 contains the fourth digit of code #2. THESE CODES MUST CONTAIN FOUR (4) DIGITS.
To disable a code, PROGRAM a "15" as the first digit of the code. These codes can be changed in the RUN mode
using the master code (see page 38, ENTERING AND CHANGING AUXILIARY CODES). User codes 8 thru 14
(locations 212-239) can be accessed from the Program Mode only.
LOCATIONS 024-027: PROGRAMMING THE DURESS CODE OR USER 7
Locations 024-027 contain the arm/disarm code for Duress or for user number 7. Duress capability is enabled by
programming a communicator code in locations 086-087. If locations 086-087 are left unprogrammed, user number 7
will act as a standard user code. If the maintenance code option is selected in location 167, locations 024-027 should
not be programmed.