24
LOCATION 197: FORCE ARMING
Force Arming is a feature that will allow the Ranger 8600E to be armed without all zones secure (no "Ready" LED
illuminated). At the end of the exit delay, all unsecured zones will automatically bypass, while all secure (Ready) zones
will be armed and active in the system. Factory default is "0", Force Arming disabled. Program a "1" to enable Force
Arming. In either case, all zones (excluding 24-hour zones) will be delayed during the exit delay. Force Arming shall be
disabled ("0") for UL Listed systems. NOTE: All zones (excluding 24-hour zones) are delayed during the exit delay
time. Programming a "2" in this location will make Instant zones "Instant" during the exit delay time.
LOCATIONS 198-201: AUTOMATIC ARMING TIME
Locations 198-201 contain the time for automatic arming if enabled in location 202. Enter the time in 24-hour (military)
time.
LOCATION 202: AUTOMATIC ARMING
Programming a "1" in location 202 will enable Automatic arming. The arming time is programmed in location 198-201. If
automatic arming is enabled, the keypad sounder will activate for 50 seconds before automatically arming. If the
sounder is silenced by entering a valid arm/disarm code during the 50-second time frame, the panel will not arm. If the
sounder is still on at the end of 50 seconds, the control will arm. Any zones not secured will be bypassed when
automatic arming is used. This feature shall be disabled for UL listed systems.
LOCATION 203: DYNAMIC BATTERY TEST
The number programmed in location 203 determines the number of minutes (1 to 15) the 8600E will perform dynamic
battery testing during each 24-hour period. The red "Power" LED will flash if the battery fails the dynamic test. Factory
default is "0" (disabled). NOTE: The clock must be set (locations 153-161) for dynamic battery test to function.
LOCATION 204: DUAL REPORTING - PROGRAMMING TAMPER, DOWNLOAD COMPLETE AND AUTOTEST TO
REPORT TO THE BOTH PHONE NUMBERS
The 8600E is capable of sending certain reports to both the primary and secondary phone numbers. When using dual
reporting, the primary phone number always takes priority over the secondary number. There are 7 reports that can be
individually programmed to report to both phone numbers. Location 204 is used to force up to three of these individual
reports to both numbers. To program tamper, download complete, or autotest to report to both numbers, use the
following chart and program the appropriate data in location 204.
REPORT TO BOTH PHONE NUMBERS
DATA TO PROGRAM IN LOCATION 204
Autotest
"2
Download Complete
"4"
Download Complete ; Autotest
"6"
Tamper
"8"
Tamper ; Autotest
A = "10"
Tamper ; Download Complete
C = "12"
Tamper ; Download Complete ; Autotest
E = "14"
LOCATION 205: DUAL REPORTING - PROGRAMMING AC POWER FAIL, LOW BATTERY, OPEN/CLOSE, AND
MAINTENANCE OPEN/CLOSE TO REPORT TO THE PRIMARY AND SECONDARY PHONE NUMBERS
The 8600E is capable of sending certain reports to both the primary and secondary phone numbers. When using dual
reporting, the primary number always takes priority over the secondary number. There are 7 reports that can be
programmed to report to both numbers. Location 205 is used to force up to four of these individual reports to both
phone numbers. To program AC power fail, low battery, open/close, or maintenance code open/close to report to both
numbers, use the following chart and program the appropriate data in this location.