background image

 

 

 

 

 

33 

 

APPENDIX 2 - REPORTING IN CONTACT ID 

 
The 8600E has the ability to report Ademco Contact ID transmissions to either or both phone numbers. Each report in 
Contact ID consists of an Event Code and a Zone or User ID. The zone or User ID is programmed in the first digit of each 
report. When programming the event code (the second digit) for zones 1-8 (locations 105, 107, 109, 111, 113, 115, 117, or 
119), programming a zero will cause the event code to follow the zone type for that zone. The event code for the zone type 
can be overridden by programming a digit from the table below.  Duress (location 87), AUX 1 (location 89), AUX 2 (location 
91), and keypad Panic (location 93) must be programmed from the table below: 
 

Programmed Event Code 

Contact ID Code 

Description 

 

122 

Silent Panic (for Loc. 93 only) 

1 110 

Fire 

Alarm 

2 120 

Panic 

alarm 

3 130 

Burglary 

Alarm 

4 131 

Perimeter 

Alarm 

5 132 

Interior 

Alarm 

6 133 

24-hour 

Burglary 

7 134 

Entry 

Alarm 

8 135 

Day/Night 

Alarm 

9 150 

Non-Burglary 

24-hour 

10 121 

Duress 

Alarm 

11 

100 

Medical Alarm (Not used for UL

12 

123 

Audible Panic Alarm 

13 137 

Tamper 

Alarm 

14 602 

Periodic 

Test 

15 

300 

System Fault  

 

 

The following reports will send fixed event codes regardless of the number programmed in the event code location: 
 
 

  Event 

Contact ID Code 

Event Code Location 

 

Keypad Tamper 

137 

 95 

Download Complete 

412 

 97 

Autotest 602 

 

99 

Failed to Communicate 

354 

101 

Closing 401 

102 

Opening 401 

103 

AC Loss 

301 

121 

Low Battery 

302 

123 

Trouble 380 

124 

Bypass 570 

125 

Restore  *  

126 

Cancel 406 

127 

Maintenance Open 

401 

172 

Maintenance Close 

401 

173 

Exit Error 

138 

210 

Recent Closing 

401 

211 

Auxiliary 3 

140 

253 

User on site 

605 

254 

 

 

* This will send the event code for the zone restored. 
 

Summary of Contents for Ranger 8600E

Page 1: ...o Program the Ranger 8600E 7 Keypad Programming Examples 8 Programming Phone Numbers Formats 9 Communicator Format Selection Guide 10 Optional Programming Instructions 10 27 Download Programming Instr...

Page 2: ...r 8600E functions After installation of the security system complete the information on page 1 of the users manual and explain the system operation to all security system owners operators Standard Par...

Page 3: ...e programmed for dual and or split reporting DYNAMIC BATTERY TEST When enabled in location 203 the 8600E can be programmed to perform a dynamic battery test for a selected duration at 6 00 AM ENTRY GU...

Page 4: ...iration program a 4 For a bell test at closing kissoff program an 8 The 8600E allows downloading of custom information to 9050 LCD keypads The 8600E has a Fire Alarm Verification feature which can be...

Page 5: ...5 Terminal Drawing Special Notes...

Page 6: ...d be 15 watt at 8 or 16 ohm or 30 40 watt at 4 8 or 16 ohms If siren driver disable is selected in location 132 output becomes voltage output 12VDC 1 Amp maximum load 16 17 Smoke detector power 12VDC...

Page 7: ...9 you would determine that the data in location 000 is 9 2 If the data in location 000 is 6 the LED for zone 2 2 and zone 3 4 would be added 2 4 6 indicating the data in that location to be 6 3 If no...

Page 8: ...8...

Page 9: ...s a local only control LOCATION 053 DISABLING THE SECONDARY TELEPHONE NUMBER AS A BACKUP Location 053 is used to disable the secondary phone number as a backup This feature can be used with split repo...

Page 10: ...G THE MASTER ARM DISARM CODE Locations 000 003 contain master arm disarm code user number 1 Location 000 contains the first digit of the code location 003 contains the fourth digit of the code THE COD...

Page 11: ...ime of 12 minutes NOTE This location shall be programmed for a minimum of 4 minutes on UL Listed systems LOCATIONS 078 083 PROGRAMMING THE ZONE TYPES Locations 078 through 083 contain a number identif...

Page 12: ...keys are pressed simultaneously on the keypad The desired Keypad panic code is programmed in locations 092 093 If both locations are 0 the Keypad panic double keypress is disabled Location 092 contai...

Page 13: ...h time zone 1 creates an alarm Location 104 contains the standard digit and location 105 contains the extended digit When using 4 2 format the number programmed in location 104 is sent as the ones dig...

Page 14: ...format is selected the restorals will be reported by zone If a restoral code is programmed and an extended format is not selected a restoral code will be sent when all of the previously reported cond...

Page 15: ...15...

Page 16: ...for the appropriate phone number s before ending the notification process If this location contains an 8 the communicator will make eight attempts to the first number and then eight attempts to a seco...

Page 17: ...sarm code VALUE DESCRIPTION 1 Activation by pressing 1 and 7 keys simultaneously 2 Momentary activation at arming 4 Momentary at end of exit delay 8 Momentary at kiss off ringback LOCATION 143 SMOKE P...

Page 18: ...ollowing chart and program the sum in this location For example to reverse outputs 2 and 3 program a 6 2 4 6 in location 149 VALUE DESCRIPTION 1 Invert auxiliary 1 output 2 Invert auxiliary 2 output 4...

Page 19: ...the 24 hour time is 17 25 so this location should contain a 1 which is the current hour tens digit If the current time is 9 36 AM the 24 hour time is 09 36 so this location should contain a 0 LOCATION...

Page 20: ...s 086 087 NOTE FOR U L GRADE A INSTALLATIONS THIS FEATURE SHALL BE DISABLED LOCATION 168 171 PROGRAMMING THE SEED CODE FOR ROTATING MAINTENANCE CODES Locations 168 171 contain the complex or seed code...

Page 21: ...G PROGRAMMING TAMPER DOWNLOAD COMPLETE AND AUTOTEST TO REPORT TO THE SECONDARY PHONE NUMBER The 8600E is capable of sending certain reports to the secondary telephone number This feature known as spli...

Page 22: ...r of 10 second increments in the secondary entry delay This delay can be programmed from 10 to 150 seconds 1 10 sec thru 15 150 sec NOTE ACCORDING TO SEC 26 OF U L 1023 THE SECONDARY ENTRY TIME SHALL...

Page 23: ...keypad sounder and a 3 will activate both any time a phone line fault is detected A 9 will activate the siren a 10 will activate the keypad sounder and an 11 will activate both if a line fault is det...

Page 24: ...tery testing during each 24 hour period The red Power LED will flash if the battery fails the dynamic test Factory default is 0 disabled NOTE The clock must be set locations 153 161 for dynamic batter...

Page 25: ...ocation 207 controls the use of the callback telephone number The callback number must be programmed in the download section for this location to have an effect The callback number will be used accord...

Page 26: ...34 will be used LOCATION 241 LISTEN IN TIME Location 241 is used to program Listen In time in 30 second increments Valid entries are 1 3 1 30 3 90 LOCATION 242 RESERVED LOCATION 243 ENTRY KEYPAD SOUND...

Page 27: ...ted in the instructions provided with the CADDX download software package LOCATIONS 264 279 CALL BACK TELEPHONE NUMBER The presence of a phone number in locations 264 279 will cause the control panel...

Page 28: ...Time Out 2 Minute Increments 4 8 Minutes 078 11 Zone 1 Type 3 Entry Exit 079 11 Zone 2 Type Locations 078 083 5 Int Follower 080 11 Zone 3 Type DATA TYPE DATA TYPE 6 Instant 081 11 Zone 4 Type 1 Day Z...

Page 29: ...utput 2 1 Fire Alarm 147 17 Auxiliary Output 3 2 Panic Duress 148 17 Auxiliary Output 4 3 Armed State 149 18 Inverting The Auxiliary Outputs 0 High Going Low 150 18 Delay Ac Power Loss Report 3 6 Minu...

Page 30: ...ng Hour Tens Digit 2 199 24 Time For Automatic Arming Hour Ones Digit 0 200 24 Time For Automatic Arming Minute Tens Digit 0 201 24 Time For Automatic Arming Minute Ones Digit 0 202 24 Automatic Armin...

Page 31: ...ith the National Electrical Code ANSI and NFPA standards When the built in digital communicator is utilized in conjunction with a U L installation it must report at a minimum a burglary zone a fire zo...

Page 32: ...ent Code SIA Code Description 1 FA Fire Alarm 2 PA Panic alarm 3 BA Burglary Alarm 4 GA Gas Alarm 5 KA Heat Alarm 6 WA Water Alarm 7 QA Emergency Alarm 8 SA Sprinkler Alarm 9 UA Untyped Alarm 10 HA Ho...

Page 33: ...ption 0 122 Silent Panic for Loc 93 only 1 110 Fire Alarm 2 120 Panic alarm 3 130 Burglary Alarm 4 131 Perimeter Alarm 5 132 Interior Alarm 6 133 24 hour Burglary 7 134 Entry Alarm 8 135 Day Night Ala...

Page 34: ...rect the situation The customer also has the right to bring a complaint to the FCC if he feels the disconnection is not warranted CHANGES IN TELEPHONE COMPANY EQUIPMENT OR FACILITIES The telephone com...

Page 35: ...G IF ANY DEFECT APPEARS DURING THE WARRANTY PERIOD RETURN IT TO CADDX POSTAGE PREPAID THE UNIT WILL BE REPAIRED AND RETURNED FOR THE REMAINING 36 MONTHS OF WARRANTY THE UNIT WILL BE REPAIRED FOR A FEE...

Reviews: