LOCATIONS 000-003: PROGRAMMING THE MASTER ARM/DISARM CODE
Locations 000-003 contain master arm/disarm code (user number 1). Location 000 contains the first digit of the code;
location 003 contains the fourth digit of the code. THE CODE MUST CONTAIN FOUR (4) DIGITS. The master code
can then be used in the run mode to enter arm/disarm codes 1-7.
LOCATIONS 004-023: PROGRAMMING THE ARM/DISARM CODE FOR USERS 2 THRU 6
Locations 004-023 contain the arm/disarm codes for user numbers 2 thru 6. Location 004 contains the first digit of the
code #2, and location 007 contains the fourth digit of code #2. THESE CODES MUST CONTAIN FOUR (4) DIGITS.
To disable a code, program a "15" as the first digit of the code. These codes can be changed in the RUN mode using
the master code.
LOCATIONS 024-027: PROGRAMMING THE DURESS CODE OR USER 7
Locations 024-027 contain the arm/disarm code for Duress or for user number 7. Duress capability is enabled by
programming a communicator code in locations 086-087. If locations 086-087 are left unprogrammed, user number 7
will act as a standard user code. If the maintenance code option is selected in location 167, locations 024-027 should
not be programmed.
LOCATIONS 028-031: PROGRAMMING THE "GO TO PROGRAM" ACCESS CODE
Locations 028-031 contain the "Go To Program" access code. Location 028 contains the first digit of the code and
location 031 contains the fourth digit of the code. THE CODE MUST CONTAIN FOUR (4) DIGITS. With the Ranger
8980 disarmed, the "Go To Program" access code can be used to enter the program mode. To disable the "Go To
Program" access code, program a "15" in location 028. The factory default setting is [9]-[7]-[1]-[3].
LOCATIONS 032-074: SEE PAGES 8 & 9
LOCATION 075: PROGRAMMING THE ENTRY DELAY TIME
Location 075 contains the number of 10 second increments in the entry delay. The entry delay can be programmed in
10 second increments from 10 to 150 seconds ("1" = 10 seconds through "15" = 150 seconds). For example,
programming a "2" in this location will produce an entry delay of 20 seconds. (Note: A "0" entry is treated as 0
seconds). Programming a "6" in this location will produce an entry delay of 60 seconds. Factory default is 30 seconds.
LOCATION 076: PROGRAMMING THE EXIT DELAY TIME
Location 076 contains the number of 10 second increments in the exit delay. The exit delay can be programmed in 10
second increments from 10 to 150 seconds ("1" = 10 seconds through "15" =150 seconds). For example, programming
a "2" in this location will produce an exit delay of 20 seconds. (Note: A "0" entry is treated as 0 seconds). Programming
a "6" in this location will produce an exit delay of 60 seconds. Factory default is 60 seconds.
LOCATION 077: PROGRAMMING THE SIREN SHUTDOWN/RECYCLE TIMEOUT
Location 077 contains the number of 2 minute increments in the automatic cutoff time. The automatic cutoff time can
be programmed in 2 minute increments from 2 to 30 minutes ("1" = 2 min thru "15" = 30 min). For example,
programming a "2" in this location will produce an automatic cutoff time of 4 minutes. Programming a "6" in this