LOCATION 130: ENABLING THE SWINGER SHUTDOWN

 

 
Location 130 is used to enable the burglary zone swinger shutdown. The number programmed in this location will 
determine the number of trips the Ranger 8980 will allow, before bypassing all burglary zones (1-8) which have tripped 
during an arming cycle. The bypassed zones will not report trips to a central station, and the local siren or bell will not 
sound for these zones. A zone trip will not be added to the number count until after the zone has tripped more than 
once.  If this location contains a "0", this feature is disabled. A zone which has been bypassed by this feature will be 
reported  if  bypass  reporting  is  enabled  in  location  125.

    NOTE:  If  Immediate  Restore  By  Zone  is  enabled  in 

Location 137, multiple reports may be transmitted during a siren cycle without adding to the trip count.

 

 

LOCATION 131: AUTOMATIC BYPASS / INSTANT ARMING

 

 
Location 131 is used to enable automatic "Instant Arming". Programming a "1" in this location will cause the control to 
automatically enter the "Instant" mode and bypass interior follower zones if a fault is not detected on an entry/exit zone 
during the exit delay.  Programming a "3" in this location (Automatic Bypass), will cause the interior follower zones to 
become bypassed if a fault is not detected on an entry/exit zone, yet will not change the status of the entry/exit zone. If 
this location contains a "0", these features are disabled.  Pressing the [

r

] key when the system is armed, will cause the 

"Instant" light to toggle. When the "Instant" light is on, the entry/exit zone is instant; when off, the entry/exit zone is 
delayed. The [

r

] key will toggle the "Instant" mode regardless of the programming data in this location. 

 

LOCATION 132: BUILT-IN SIREN DRIVER / 1 AMP VOLTAGE OUTPUT

 

 
The built-in siren driver has a steady sound (for Priority zone type), and a yelp sound (for Burglary and Panic). Factory 
default is "0", enabling this feature. If the built-in siren driver is 

NOT 

to be used, take the following procedure. First, 

remove the jumper marked voltage/siren on the PC board. Next, program a "1" in location 132. Finally, replace the 
jumper in the voltage position. Terminals 21 & 22 will now output 1 Amp at 12VDC. 
 

LOCATION 133: L.E.D. EXTINGUISH FEATURE

 

 
Keypad  LEDs  (excluding  the  A.C.  LED)  will  be  extinguished  after  60  seconds  of  keypad  inactivity,  if  a  "1"  is 
programmed in location 133. The LEDs will become illuminated immediately upon a keypress or alarm condition. 
 

LOCATION 134: ENTERING THE NUMBER OF DIAL ATTEMPTS

 

 
Location  134  is  used  to  enter  the  number  of  dial  attempts  (1  to  15  attempts)  the  communicator  will  try  for  the 
appropriate phone number(s) before ending the notification process. If this location contains an "8", the communicator 
will make eight attempts to the first number, and then eight attempts to a second number, if a second number is 
programmed as backup.  
 

LOCATION 135: POWER UP CONDITION

 

 
If a "1" is programmed in location 135, the Ranger 8980 will power-up disarmed if there is a total power shutdown and 
battery failure. If a "2" is programmed in this location, it will power up armed. If this location contains a "0", the Ranger 
8980 will power up in the condition it was in at power down. A watchdog circuit reset will cause the Ranger 8980 to 
reset to the selected condition. 
 

LOCATION 136: POWER UP DELAY

 

 
If a "1" is programmed in location 136, the Ranger 8980 will not delay 60 seconds before accepting open or short 
inputs from any zone.  If a "0" is programmed, sensors on all zones are allowed 60 seconds to stabilize at power-up. 
After 60 seconds, the Ranger will once again accept loop opens or shorts as an alarm condition. This 60-second 
period will also be initiated after exiting the program mode, or a watchdog circuit reset condition. 
 

LOCATION 137: IMMEDIATE RESTORE BY ZONE

 

 
If a "1" is programmed in location 137, restoral signals will follow the restore condition and report restores immediately 
after the condition has unfaulted. A non-extended format will not send a restore message until all zones and trouble 
conditions have restored. If this location contains a "0", the restore signal or signals will be reported only after siren 
timeout. 
 

Summary of Contents for Ranger 8980

Page 1: ...PTION 4 HOW TO PROGRAM THE RANGER 8980 6 KEYPAD PROGRAMMING EXAMPLES 7 PROGRAMMING PHONE NUMBERS FORMATS 8 9 COMMUNICATOR FORMAT SELECTION GUIDE 9 OPTIONAL PROGRAMMING INSTRUCTIONS 10 22 AVAILABLE ZON...

Page 2: ...he Ranger 8980 functions After installation of the security system complete the information on page 1 of the users manual and explain the system operation to all security system owners operators Stand...

Page 3: ...3 PARTS DIAGRAM...

Page 4: ......

Page 5: ...e Ring red 20 R1 House Telephone Ring gray 21 22 Siren driver output to speaker s speaker rating should be 15 watt at 8 or 16 ohm or 30 40 watt at 4 8 or 16 ohms If siren driver disable is selected in...

Page 6: ...icating the data in that location to be 6 If no LED s are illuminated the location contains a 0 To advance from location 000 through 180 press the key To go to a specific location press the location n...

Page 7: ...8...

Page 8: ...1800HZ 2300HZ Fast with Parity and Hex Capability requires a 9 in this location If you need another format choose from those listed on the format table located on page 13 and program the data in loca...

Page 9: ...Z HANDSHAKE DOUBLE ROUND PARITY 20 PPS 5 EXTENDED RADIONICS SLOW 1800HZ TRANSMIT 2300HZ HANDSHAKE DOUBLE ROUND PARITY 20 PPS EXTENDED HEX CAPABILITY 6 EXTENDED RADIONICS SLOW 1800HZ TRANSMIT 1400HZ HA...

Page 10: ...GITS With the Ranger 8980 disarmed the Go To Program access code can be used to enter the program mode To disable the Go To Program access code program a 15 in location 028 The factory default setting...

Page 11: ...8980 is armed or disarmed An open will create a Trouble condition Keypad LED will be steady for FIRE and flashing for Trouble 9 SECONDARY DELAY A secondary delay zone works like an entry exit delay zo...

Page 12: ...rammed in location 094 is sent as the ones digit The tens digit is programmed in location 095 LOCATION 096 097 PROGRAMMING TO REPORT DOWNLOADING COMPLETE Locations 096 097 contain the communicator rep...

Page 13: ...ZONE 4 Locations 110 111 contain the communicator code to be reported each time zone 4 creates an alarm Location 110 contains the standard digit and location 111 contains the extended digit When usin...

Page 14: ...a bypass immediately When a bypass is removed a restore will be reported if Restore is enabled in location 126 LOCATION 126 PROGRAMMING THE COMMUNICATOR CODE FOR RESTORAL Location 126 contains the co...

Page 15: ...he following procedure First remove the jumper marked voltage siren on the PC board Next program a 1 in location 132 Finally replace the jumper in the voltage position Terminals 21 22 will now output...

Page 16: ...d a 1 is programmed in location 141 all reports will be double line extended If location 141 contains a 0 only non alarm reports will be extended restore cancel opening closing bypass and trouble With...

Page 17: ...ORITY SIREN RECYCLED OUTPUT 4 ARMED WITH BYPASS LATCHED OUTPUT 5 AC POWER LATCHED OUTPUT 6 LOW BATTERY LATCHED OUTPUT 7 ALARM MEMORY LATCHED OUTPUT 8 ENTRY LATCHED OUTPUT 9 EXIT MOMENTARY OUTPUT LOCAT...

Page 18: ...55 contains the current year ones digit If the current year is 1994 this location should contain a 4 which is the ones digit of the current year If the current year is 1995 this location should contai...

Page 19: ...t of the minutes after the hour that the autotest is desired The time is entered in 24 hour time If the desired autotest time is 5 25 PM the 24 hour time is 17 25 so this location should contain a 2 w...

Page 20: ...ime user number 7 arms the control The desired closing code should be programmed in this location This feature can be used in conjunction with the rotating maintenance code to give a closing report ea...

Page 21: ...ST TO REPORT TO THE SECONDARY PHONE NUMBER The 8980 is capable sending certain reports to the secondary telephone number This feature known as split reporting can be used to send alarm reports to one...

Page 22: ...9 AC FAIL OPEN CLOSE A 10 AC FAIL OPEN CLOSE MAINT CODE OPEN CLOSE B 11 AC FAIL LOW BATTERY C 12 AC FAIL LOW BATTERY MAINT CODE OPEN CLOSE D 13 AC FAIL LOW BATTERY OPEN CLOSE E 14 AC FAIL LOW BATTERY...

Page 23: ...umber programmed in location 210 maximum 3 The control panel will detect these rings and start a 45 second timer If a call comes in during that 45 second time frame the control panel will answer on th...

Page 24: ...SECONDARY ACCOUNT CODE 0 DISABLED 074 9 SECONDARY FORMAT 0 DISABLED CONTROL COMMUNICATOR FEATURES LOCATION PAGE DESCRIPTION DATA DEFAULT 075 10 ENTRY DELAY TIME 10 SECOND INCREMENTS 3 30 SECONDS 076...

Page 25: ...ANT ARMING 0 DISABLED 132 15 SIREN DRIVER OR VOLTAGE OUTPUT 0 SIREN DRIVER 133 15 LED EXTINGUISH FEATURE 0 DISABLED 134 15 NUMBER OF DIAL ATTEMPTS 8 EIGHT ATTEMPTS 135 15 POWER UP CONDITION 0 LAST CON...

Page 26: ...DIGIT 4 0 172 20 USER 7 MAINTENANCE CODE OPENING REPORT 0 DISABLED 173 20 USER 7 MAINTENANCE CODE CLOSING REPORT 0 DISABLED 174 20 PROGRAM ZONES 3 THRU 6 FOR NORMALLY CLOSED OPERATION 0 SUPERVISED 17...

Page 27: ...rect the situation The customer also has the right to bring a complaint to the FCC if he feels the disconnection is not warranted CHANGES IN TELEPHONE COMPANY EQUIPMENT OR FACILITIES The telephone com...

Page 28: ...G IF ANY DEFECT APPEARS DURING THE WARRANTY PERIOD RETURN IT TO CADDX POSTAGE PREPAID THE UNIT WILL BE REPAIRED AND RETURNED FOR THE REMAINING 36 MONTHS OF WARRANTY THE UNIT WILL BE REPAIRED FOR A FEE...

Reviews: