20
LOCATION 168-171: PROGRAMMING THE SEED CODE FOR ROTATING MAINTENANCE CODES
Locations 168-171 contain the complex, or "seed code" required to generate rotating maintenance codes as described
in the paragraph above. These locations allow a unique set of codes for different buildings or complexes. NOTE:
ACTIVATING THE MAINTENANCE CODE WILL AUTOMATICALLY DISABLE THE DURESS CODE, REGARDLESS
OF WHAT IS PROGRAMMED IN LOCATIONS 086-087.
LOCATION 172: PROGRAMMING USER 7 OR MAINTENANCE CODE OPENING COMMUNICATOR CODE
The Ranger 8980 has the ability to give an opening report each time user number 7 disarms the control. The desired
opening code should be programmed in this location. This feature can be used in conjunction with the rotating
maintenance code to give an opening report each time the maintenance code is used to disarm. When using an
extended format, the extended code will always be a 7.
LOCATION 173: PROGRAMMING USER 7 OR MAINTENANCE CODE CLOSING COMMUNICATOR CODE
The Ranger 8980 has the ability to give a closing report each time user number 7 arms the control. The desired
closing code should be programmed in this location. This feature can be used in conjunction with the rotating
maintenance code to give a closing report each time the maintenance code is used to arm. When using an extended
format, the extended code will always be a 7. CAUTION! If a "Quick Arm" code has been selected, and the first digit of
the rotating maintenance code is the same digit as the "Quick Arm" code, the maintenance closing code will not be
reported.
LOCATION 174: PROGRAMMING ZONES 3 THRU 6 FOR NORMALLY CLOSED OPERATION ONLY
Location 174 is used to program zones 3,4,5,& 6 for normally closed operation only, eliminating the need for the end of
line resistors on that zone. When a zone is programmed for normally closed operation only, a short will not change the
loop condition, and an open on that zone will produce a faulted condition. This feature will be ignored by any Priority
zone. To program a zone for normally closed only, refer to the chart below, and program the appropriate data in this
location.
ZONES TO PROGRAM FOR N/C OPERATION
DATA T0 PROGRAM IN LOCATION 174
6
"1"
5
"2"
5 & 6
"3"
4
"4"
4 & 6
"5"
4 & 5
"6"
4, 5, & 6
"7"
3
"8"
3 & 6
"9"
3 & 5
A ="10"
3, 5, & 6
B ="11"
3 & 4
C ="12"
3, 4, & 6
D ="13"
3, 4, & 5
E ="14"
3, 4, 5, & 6
F ="15"