background image

 

 25 

 

LOCATION

 

PAGE

 

DESCRIPTION

 

ZONE ID

 

EVENT/EXT CODE

 
DEFAULT

 

103 

 

12 

 
OPENING COMMUNICATOR CODE 

 

 

 

MAN NUMBER 

 
"0" DISABLED 

 

104-105 

 

13 

 
ZONE 1 COMMUNICATOR CODE 

 

 

 

 

 
"1 - 0" 

 

106-107 

 

13 

 
ZONE 2 COMMUNICATOR CODE 

 

 

 

 

 
"2 - 0" 

 

108-109 

 

13 

 
ZONE 3 COMMUNICATOR CODE 

 

 

 

 

 
"3 - 0" 

 

110-111 

 

13 

 
ZONE 4 COMMUNICATOR CODE 

 

 

 

 

 
"4 - 0" 

 

112-113 

 

13 

 
ZONE 5 COMMUNICATOR CODE 

 

 

 

 

 
"5 - 0" 

 

114-115 

 

13 

 
ZONE 6 COMMUNICATOR CODE 

 

 

 

 

 
"6 - 0" 

 

116-117 

 

13 

 
ZONE 7 COMMUNICATOR CODE 

 

 

 

 

 
"7 - 0" 

 

118-119 

 

13 

 
ZONE 8 COMMUNICATOR CODE 

 

 

 

 

 
"8 - 0" 

 

120-121 

 

14 

 
AC POWER LOSS COMMUNICATOR CODE 

 

 

 

 

 
"0" DISABLED 

 

122-123 

 

14 

 
LOW BATTERY COMMUNICATOR CODE 

 

 

 

 

 
"0" DISABLED 

 

124 

 

14 

 
TROUBLE COMMUNICATOR CODE 

 

 

 

ZONE NUMBER 

 
"0" DISABLED 

 

125 

 

14 

 
ZONE BYPASS COMMUNICATOR CODE 

 

 

 

ZONE NUMBER 

 
"0" DISABLED 

 

126 

 

14 

 
RESTORE COMMUNICATOR CODE 

 

 

 

ZONE NUMBER 

 
"0" DISABLED 

 

127 

 

14 

 
CANCEL COMMUNICATOR CODE 

 

 

 

MAN NUMBER 

 
"0" DISABLED 

 

 

LOCATION

 

PAGE

 

DESCRIPTION

 

DATA

 
DEFAULT

 

128 

 

14 

 
ABORT COMMUNICATOR CODE 

 

 

 
"0" DISABLED 

 

129 

 

14 

 
KEYPAD PANIC SILENT OR AUDIBLE 

 

 

 
"0" AUDIBLE 

 

130 

 

15 

 
NUMBER OF ALARMS FOR SWINGER SHUTDOWN 

 

 

 
"0" DISABLED 

 

131 

 

15 

 
AUTO BYPASS/ INSTANT ARMING 

 

 

 
"0" DISABLED 

 

132 

 

15 

 
SIREN DRIVER OR VOLTAGE OUTPUT 

 

 

 
"0" SIREN DRIVER 

 

133 

 

15 

 
LED EXTINGUISH FEATURE 

 

 

 
"0" DISABLED 

 

134 

 

15 

 
NUMBER OF DIAL ATTEMPTS 

 

 

 
"8" EIGHT ATTEMPTS 

 

135 

 

15 

 
POWER UP CONDITION 

 

 

 
"0" LAST CONDITION 

 

136 

 

15 

 
POWER UP DELAY 

 

 

 
"0" 60 SEC DELAY 

 

137 

 

15 

 
IMMEDIATE RESTORE BY ZONE 

 

 

 
"0" DISABLED 

 

138 

 

16 

 
NO ARMING WITH ZONE BYPASSED 

 

 

 
"0" DISABLED 

 

139 

 

16 

 
QUICK ARM DIGIT 

 

 

 
"0" DISABLED 

 

140 

 

16 

 
FIRE SIREN CUTOFF INHIBIT 

 

 

 
"0" RECYCLES 

 

141 

 

16 

 
DOUBLE LINE EXTENDED REPORTING 

 

 

 
"0" DISABLED 

 

142 

 

16 

 
SIREN/BELL TEST FEATURE 

 

 

 
"0" DISABLED 

 

143 

 

16 

 
RESETTABLE AUXILIARY POWER 

 

 

 
"1" POWER RESET 

 

144 

 

16 

 
EUROPEAN PULSE DIAL RATIO 

 

 

 
"0" DISABLED 

 

145 

 

17 

 
AUXILIARY OUTPUT #1 

 

 

 
"0" ARMED 

 

146 

 

17 

 
AUXILIARY OUTPUT #2 

 

 

 
"1" READY 

 

147 

 

17 

 
AUXILIARY OUTPUT #3 

 

 

 
"2" BURG SIREN 

 

148 

 

17 

 
AUXILIARY OUTPUT #4 

 

 

 
"3" FIRE SIREN 

 

149 

 

17 

 
INVERTING THE AUXILIARY OUTPUTS 

 

 

 
"0" HIGH GOING LOW 

 

150 

 

17 

 
AC POWER LOSS  DELAY 

 

 

 
"0" DELAYED 

 

151 

 

18 

 
NUMBER OF RINGS TO ANSWER DOWNLOAD CALL 

 

 

 
"8" EIGHT RINGS 

 

152 

 

18 

 
NUMBER OF DAYS LEFT UNTIL AUTOTEST 

 

 

 
UNDEFINED 

 

153 

 

18 

 
PROGRAM CLOCK, CURRENT MONTH 

 

 

 
UNDEFINED 

 

154 

 

18 

 
PROGRAM CLOCK, CURRENT YEAR - TENS DIGIT (19

9

4)  

 

 

 
UNDEFINED 

 

155 

 

18 

 
PROGRAM CLOCK, CURRENT YEAR - ONES DIGIT (199

4) 

 

 

 

 
UNDEFINED 

 

156 

 

18 

 
PROGRAM CLOCK, CURRENT DAY OF MONTH - TENS DIGIT  

 

 

 
UNDEFINED 

Summary of Contents for Ranger 8980

Page 1: ...PTION 4 HOW TO PROGRAM THE RANGER 8980 6 KEYPAD PROGRAMMING EXAMPLES 7 PROGRAMMING PHONE NUMBERS FORMATS 8 9 COMMUNICATOR FORMAT SELECTION GUIDE 9 OPTIONAL PROGRAMMING INSTRUCTIONS 10 22 AVAILABLE ZON...

Page 2: ...he Ranger 8980 functions After installation of the security system complete the information on page 1 of the users manual and explain the system operation to all security system owners operators Stand...

Page 3: ...3 PARTS DIAGRAM...

Page 4: ......

Page 5: ...e Ring red 20 R1 House Telephone Ring gray 21 22 Siren driver output to speaker s speaker rating should be 15 watt at 8 or 16 ohm or 30 40 watt at 4 8 or 16 ohms If siren driver disable is selected in...

Page 6: ...icating the data in that location to be 6 If no LED s are illuminated the location contains a 0 To advance from location 000 through 180 press the key To go to a specific location press the location n...

Page 7: ...8...

Page 8: ...1800HZ 2300HZ Fast with Parity and Hex Capability requires a 9 in this location If you need another format choose from those listed on the format table located on page 13 and program the data in loca...

Page 9: ...Z HANDSHAKE DOUBLE ROUND PARITY 20 PPS 5 EXTENDED RADIONICS SLOW 1800HZ TRANSMIT 2300HZ HANDSHAKE DOUBLE ROUND PARITY 20 PPS EXTENDED HEX CAPABILITY 6 EXTENDED RADIONICS SLOW 1800HZ TRANSMIT 1400HZ HA...

Page 10: ...GITS With the Ranger 8980 disarmed the Go To Program access code can be used to enter the program mode To disable the Go To Program access code program a 15 in location 028 The factory default setting...

Page 11: ...8980 is armed or disarmed An open will create a Trouble condition Keypad LED will be steady for FIRE and flashing for Trouble 9 SECONDARY DELAY A secondary delay zone works like an entry exit delay zo...

Page 12: ...rammed in location 094 is sent as the ones digit The tens digit is programmed in location 095 LOCATION 096 097 PROGRAMMING TO REPORT DOWNLOADING COMPLETE Locations 096 097 contain the communicator rep...

Page 13: ...ZONE 4 Locations 110 111 contain the communicator code to be reported each time zone 4 creates an alarm Location 110 contains the standard digit and location 111 contains the extended digit When usin...

Page 14: ...a bypass immediately When a bypass is removed a restore will be reported if Restore is enabled in location 126 LOCATION 126 PROGRAMMING THE COMMUNICATOR CODE FOR RESTORAL Location 126 contains the co...

Page 15: ...he following procedure First remove the jumper marked voltage siren on the PC board Next program a 1 in location 132 Finally replace the jumper in the voltage position Terminals 21 22 will now output...

Page 16: ...d a 1 is programmed in location 141 all reports will be double line extended If location 141 contains a 0 only non alarm reports will be extended restore cancel opening closing bypass and trouble With...

Page 17: ...ORITY SIREN RECYCLED OUTPUT 4 ARMED WITH BYPASS LATCHED OUTPUT 5 AC POWER LATCHED OUTPUT 6 LOW BATTERY LATCHED OUTPUT 7 ALARM MEMORY LATCHED OUTPUT 8 ENTRY LATCHED OUTPUT 9 EXIT MOMENTARY OUTPUT LOCAT...

Page 18: ...55 contains the current year ones digit If the current year is 1994 this location should contain a 4 which is the ones digit of the current year If the current year is 1995 this location should contai...

Page 19: ...t of the minutes after the hour that the autotest is desired The time is entered in 24 hour time If the desired autotest time is 5 25 PM the 24 hour time is 17 25 so this location should contain a 2 w...

Page 20: ...ime user number 7 arms the control The desired closing code should be programmed in this location This feature can be used in conjunction with the rotating maintenance code to give a closing report ea...

Page 21: ...ST TO REPORT TO THE SECONDARY PHONE NUMBER The 8980 is capable sending certain reports to the secondary telephone number This feature known as split reporting can be used to send alarm reports to one...

Page 22: ...9 AC FAIL OPEN CLOSE A 10 AC FAIL OPEN CLOSE MAINT CODE OPEN CLOSE B 11 AC FAIL LOW BATTERY C 12 AC FAIL LOW BATTERY MAINT CODE OPEN CLOSE D 13 AC FAIL LOW BATTERY OPEN CLOSE E 14 AC FAIL LOW BATTERY...

Page 23: ...umber programmed in location 210 maximum 3 The control panel will detect these rings and start a 45 second timer If a call comes in during that 45 second time frame the control panel will answer on th...

Page 24: ...SECONDARY ACCOUNT CODE 0 DISABLED 074 9 SECONDARY FORMAT 0 DISABLED CONTROL COMMUNICATOR FEATURES LOCATION PAGE DESCRIPTION DATA DEFAULT 075 10 ENTRY DELAY TIME 10 SECOND INCREMENTS 3 30 SECONDS 076...

Page 25: ...ANT ARMING 0 DISABLED 132 15 SIREN DRIVER OR VOLTAGE OUTPUT 0 SIREN DRIVER 133 15 LED EXTINGUISH FEATURE 0 DISABLED 134 15 NUMBER OF DIAL ATTEMPTS 8 EIGHT ATTEMPTS 135 15 POWER UP CONDITION 0 LAST CON...