INSTANT/DELAY OPTION

If checked, your installing company has selected the “INSTANT” option. With this feature
enabled, if you do not wish to have a delay on your entry/exit doors, this can be accomplished
by pressing the 

 key on your keypad while the system is “ARMED”. At this time, the

“INSTANT” light will illuminate and there will be no entry delay when the entry/exit doors are
opened. Any time the “INSTANT” light is on and the exit delay has expired, the opening of an
entry/exit door will produce an immediate alarm, making this feature ideal when a high level

of security is desired, and no authorized entries are anticipated. By pressing the 

 key again.

the “INSTANT” light will turn off, and an entry delay will be present on designated entry/exit
doors.

NOTE: Your installing 

 may have programmed the “INSTANT” option to occur in

conjunction with the “AUTOMATIC BYPASS” feature. In this case, the “INSTANT” light and the
bypassed “ZONE” lights will become illuminated at the end of the exit delay. If this occurs, you
still have the ability to turn the “INSTANT” feature off, and/or on by pressing the 

 key.

ENTRY-GUARD OPTION

If checked, your installing company has selected the “ENTRY-GUARD” option. If you wish to

arm your system in a low security mode, you may do so by pressing the preset 
GUARD” digit (see page 1 for the selected digit). Five seconds later, the security control will
bypass all non “ENTRY-GUARD” zones, and arm the system with all “Entry-Guard” zones
delayed. This mode of operation will allow you time to DISARM (turn off) the security system
in the event a zone is accidentally opened.

KEYPADACTIVATED PAN/C/HOLD-UPALARM

If checked, your installing company has selected this feature. If so, when the star 

 and

pound 

 keys are pressed at the same time for one second, a local audible alarm will sound.

If your system is connected to a monitoring center, an emergency report could be transmitted

to that center. These keys should only be pressed in an emergency situation requiring
immediate response by law enforcement personnel.

PLEASE NOTE: Some Panic/Hold-up alarrns are programmed to be silent at the protected site

while reporting an alarm to the monitoring center. Check with your installing company to
determine how your security system will respond to the Panic/Hold-up activation.

KEYPAD ACTIVATED FIRE ALARM

If checked, 

your installing company has selected this feature. If so, you can activate the steady

siren by pressing the one 

[I] 

and three 

 keys at the same time for one second. If your

system is connected to a monitoring center, an emergency report could be sent to that center.
These keys should only be pressed in an emergency situation requiring response by fire
department personnel.

q

If checked, your installing company has selected this feature. If so, you can activate the

auxiliary alarm by pressing the four 

 and six 

 keys at the same time for one second. If your

system is connected to a monitoring center, an emergency report could be sent to that center.

These keys should only be pressed in an emergency situation requiring response by
emergency personnel. When the “4” and 

 are pressed together, the keypad will start to

beep until a code is entered.

Summary of Contents for Ranger 9000E

Page 1: ...Security Control System User s Manual ...

Page 2: ...elay is present FIRE light indicates a smoke or heat detector has been activated This light is reset by pressing the reset button TROUBLE light indicates a technical problem with the fire zone This light is reset by pressing the reset button Pressing will turn off Keypad Pressing will turn off backlighting Pressing 0 will turn off both of the above PANIC HOLD UP ALARM If programmed by the installe...

Page 3: ...t Entry Guard Digit AUXILIARY ARM DISARM CODES 02 03 04 05 06 07 08 09 10 11 12 15 19 20 21 22 23 24 25 26 27 28 29 30 ENTRY EXIT DELAY TIMES Exit Delay Time Secondary Exit Delay Time Entry Delay Time Secondary Entry Delay Time ZONE DESCRIPTIONS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 18 19 20 21 22 23 24 25 26 27 28 29 30 32 ...

Page 4: ...STIONS ASK YOUR INSTALLING COMPANY PLEASE KEEP IN MIND THAT THE LEVEL OF SECURITY YOU WILL OBTAIN WITH THIS SYSTEM RELATES SPECIFICALLY WITH TWO MAJOR FACTORS 1 The quantity quality and placement of security devices attached to this system 2 The knowledge you have of the security system and how that knowledge is utilized in a weekly test of the complete system YOU SHOULD BE AWARE OF THE FOLLOWING ...

Page 5: ... delay time noted on page 1 If you choose to stay within the protected area insure that all interior zones that may be tripped by your movement are bypassed HOW TO DISARM YOUR SECURITY SYSTEM When you enter the protected area through one of the designated entry exit doors the keypad control will sound a continuous tone beep for the duration of the entry delay time or until you enter a valid code A...

Page 6: ...ll zones violated during last alarm will flash All zones that bypassed during the last alarm will be a steady light QUICK ARM FEA TURE If checked your security system has a QUICK ARM code programmed This feature will allow you to arm the security system by pressing one pre designated key on the keypad control This QUICK ARM code is for ARMING ONLY and will not disarm the security system This makes...

Page 7: ...will allow you time to DISARM turn off the security system in the event a zone is accidentally opened KEYPADACTIVATED PAN C HOLD UPALARM If checked your installing company has selected this feature If so when the star and pound keys are pressed at the same time for one second a local audible alarm will sound If your system is connected to a monitoring center an emergency report could be transmitte...

Page 8: ...s not armed While in the CHIME mode the opening of any of these zones will produce a l second beep from the keypad control To use this feature press the CHIME digit this digit has been selected by your company and is noted on page 1 Five seconds after pressing the CHIME digit a beep will occur indicating that this feature has been activated Repeat this procedure to turn the CHIME feature off SPECI...

Page 9: ... open all protected windows and doors The Keypad Control should sound beep for each device and the appropriate yellow zone light should blink Walk into all areas protected by motion detection devices while someone observes the Keypad Control The appropriate yellow zone light should blink for each sensor tested l If your system has a FIRE zone the Smoke or Heat detectors should be tested at least m...

Page 10: ... will increase your escape time If you suspect fire test the door for heat If you think it is safe brace your shoulder against the door and open it cautiously Be ready to slam the door if smoke or heat rush in Practice escaping to the outdoors and meeting in an assigned spot Call the Fire Department from a neighbor s phone NOTE After the installation of your Security System has been completed noti...

Reviews: