140
xGenConnect Installation and Programming Guide
Appendix 5: NXG-183x Keypad Features
Navigating through “Program” menu using NXG-183x-EUR keypad
NXG-183x-EUR allows the installer to configure all the configuration parameters
exposed by the panel or other peripheral devices. In order to enter programming
menu, one needs to press the ENTER key on the keypad, then enter the installer
PIN followed by ENTER.
Once entered the installer programming menu, “Program” appears as the first
submenu. The menu structure is identical to the Advanced menu structure from
the panel web page.
See also “Appendix 4: Advanced Menu Tree” on page 139.
Navigation through the Program menu is similar to operation within the user
menu, with some additional extensions:
• Top line shows the full path of the current location (for example, Zones / Zone
Number 1 / Zone Name, etc.). The path is usually too long to fit the screen
–
in such case it can be scrolled back and forth by pressing “i” key.
• If the current location is within the menu tree of enumerable objects (for
example, within Zones, Partitions, Channels, Schedules, etc.), then the object
number (for example, Zone number) can be instantly changed by either one
of the following methods:
- Pressing A button allows the installer to specify the new object by entering a
number.
- Pressing Left (4) or Right (6) buttons allows the installer to increase or
decrease the current object number within the allowed limits.
Wireless sensor learning
There are two sensor learning modes:
• Single sensor learning.
To program a single sensor, go to the menu Program / Devices / Interlogix
Transmitters, and select the sensor you want to learn. Enter
value “1” in the
transmitter serial number field, and then press Enter.
• Multiple sensor learning.
To program multiple sensors, go to the menu Program / Devices / Interlogix
Transmitters, and select the starting number for multiple sensor learning.
Enter
value “2” in the transmitter serial number field, and then press Enter.
The keypad will show “Learn Mode Active / Activate Sensor” message.
Activate the wireless sensor. Refer to the appropriate sensor manual for
information.
When a sensor is tripped for learning, the keypad shows “New Device Found /
Number: X, SID: Y”. The sensor Y is now enrolled as a transmitter number X.
In the single sensor learning mode, the information disappears after 10 s and you
return to the Interlogix Transmitters menu.
Summary of Contents for xGenConnect
Page 1: ...xGenConnect Installation and Programming Guide P N 466 5545 EN REV J ISS 26OCT22...
Page 4: ......
Page 12: ...viii xGenConnect Installation and Programming Guide...
Page 93: ...xGenConnect Installation and Programming Guide 81 Web Page...
Page 109: ...xGenConnect Installation and Programming Guide 97 Instructions 1 Go to Zone Type...
Page 117: ...xGenConnect Installation and Programming Guide 105 Webpage...
Page 156: ...144 xGenConnect Installation and Programming Guide...
Page 166: ...154 xGenConnect Installation and Programming Guide...