12
xGenConnect Installation and Programming Guide
#
SIA code CID code Function
127
JK
E102
Guard Tour Fail
128
NA
E641
Activity Monitor Fail
129
DG
E422
Valid Code Entered
130
DP
E421
Valid Code Out Of Schedule
131
DV
E421
Valid Code Void
132
DV
E421
Valid Code Lost
133
DV
E421
Valid Code Expired
134
RU
E628
Remote Program End
135
CL
E102
Man Down
136
RR
E305
Power Up
137
RR
R305
Power Up Restore
138
RX
R601
Manual Test Restore
139
OJ
E452
Late Opening
140
CK
R451
Early Closing
141
UB
E532
Device Bypass
142
UU
E531
Device Unbypass
143
YF
E304
Checksum Failure Failure
144
YG
R304
Checksum Failure Restore
145
YT
E338
Expander Low Battery
146
YR
R338
Checksum Failure Restore
147
YT
E337
DC Fail
148
YR
R337
DC Fail Restore
149
E609
Video Event
150
LT
E351
IP Path Fault
151
LR
R351
IP Path Fault Restore
152
E458
Geofence1 Entered
153
R458
Geofence1 Exited
154
E458
Geofence2 Entered
155
R458
Geofence2 Exited
156
YP
R351
Power Supply Fault
157
YQ
R351
Power Supply Restore
EN 50131-3 and EN 50136-2 Compliancy
In order to be compliant with the technical specification EN 50131-3 (Alarm
systems
– Control and indicating equipment), the following guidelines must be
taken into account:
• The tamper of the warning device should be connected to a 24-hour zone
input.
Summary of Contents for xGenConnect
Page 1: ...xGenConnect Installation and Programming Guide P N 466 5545 EN REV J ISS 26OCT22...
Page 4: ......
Page 12: ...viii xGenConnect Installation and Programming Guide...
Page 93: ...xGenConnect Installation and Programming Guide 81 Web Page...
Page 109: ...xGenConnect Installation and Programming Guide 97 Instructions 1 Go to Zone Type...
Page 117: ...xGenConnect Installation and Programming Guide 105 Webpage...
Page 156: ...144 xGenConnect Installation and Programming Guide...
Page 166: ...154 xGenConnect Installation and Programming Guide...