background image

21

LUCE   -  ELLE  -  ARCO 

FUEL

9.1 

FUEL

•  Use top-quality pellets because they have influence in the calorific value and in ash remains.

•  Not adequate pellets cause a bad combustion, a frequent burning pot obstruction and exhaust conduits obstruction. Further it 

decreases the calorific value, soils the glass and increases consumptions and ash and unburnt granules quantity.

Humid pellets cause a bad combustion and running, so please assure you that they are stored in dry places and 

far at least one meter from the stove and/or any other source of heat.

•  It is advisable to try different type of pellets available on the market and to choose that which gives the best performance.

Do not use pellets other than natural wood because they may contain very aggressive chemical components which corrode metal.

•  Pellets of variable quality and size are available on the market: the smaller the pellet, the greater the fuel supply, resulting in 

poor combustion

Depending on the type of pellets it could be necessary a parameters adjustment, please contact an Authorized 

Assistance Service.

The main quality certifications for pellets currently available on the European market guarantee that the fuel complies with class 

A1/A2 according to ISO 17225-2. These certifications include, for example, ENPlus, DINplus, Ö-Norm M7135, and specifically assure 

that the following characteristics are complied with:

•  calorific value: 4.6 - 5.3 kWh/kg.

•  Water content: ≤ 10% of the weight.

•  Percentage of ash: max 1.2% of the weight (A1 less than 0.7%).

•  Diameter: 6±1/8±1 mm.

•  Length: 3-40 mm.

•  Content: 100% untreated wood without the addition of binding agents.

The company recommends using certified fuel for its products (ENPlus A1, DINplus, Ö-Norm 

M7135).

The use of pellets that do not comply with the characteristics specified previously may compro-

mise the operation of your product and therefore invalidate the warranty and product liability.

9.2 

PELLET SUPPLY

Fig. 22 - Wrong opening of the pellets bag 

Fig. 23 - Right opening of the pellets bag

It is necessary to avoid to fill the hopper with the pellet when the stove is running.

•  Do not get the bag of pellet in contact with hot stove surfaces.

•  Do not empty the hopper with remaining fuels (unburnt pellet) from the burning pot coming from ignition waster.

Summary of Contents for ARCO 7 T1 BI-FLUX

Page 1: ...EN USER MANUAL Pellet Stove 2023CADELsrl Allrightsreserved Tuttiidirittiriservati new ARCO 7 T1 ARCO 7 T1 BI FLUX ARCO 9 T2 ARCO 9 T2 BI FLUX ELLE PLUS 9 T2 LUCE PLUS 9 T2...

Page 2: ...ONXSETTINGSMENU A PAG 13 19 8 17 PELLETS RECIPE SEE SECTION H SETTINGS MENU A PAG 13 20 8 18 SMOKE RPM VARIATION SEE SECTION I SETTINGS MENU A PAG 13 20 8 19 CHIMNEY SWEEP FUNCTION FOR MAINTENANCE TEC...

Page 3: ...includingthosereferringtonationalandEuropeanstandards mustbeobservedwheninstallingtheappliance In Italy for the installation of systems with a biomass below 35KW refer to the Ministerial Decree 37 08...

Page 4: ...these operating conditions increase the risk of premature wear of the product especially those parts exposed to the direct heat of the fire e g combustion chamber theoriginalconditionofwhichcanunderg...

Page 5: ...protector made of in combustiblematerial steel glass etc thatalsoprotectsthefrontpartfromanyfallingburnt particles during cleaning The electrical cable must not get in touch with the fume exhaust pip...

Page 6: ...ly check and empty the inspectionable parts of the smoke duct e g Tee fitting caps Have the smoke outlet system periodically checked and cleaned The product is not a cooking appliance Always keep the...

Page 7: ...Damage caused during transportation or relocation All parts that develop faults due to negligence or improper use incorrect maintenance installation that does not comply with the manufacturer s instru...

Page 8: ...e sole party responsible for demolishing and disposing of the product This must be performed in compliance with laws related to safety and environmental protection in force in his her country At the e...

Page 9: ...2 Wastedisposal Thissymbol whichisusedontheproduct batteries accumulatorsoronthepackagingordocuments meansthatattheendofits useful life this product the batteries and the accumulators included must no...

Page 10: ...com petent body APPLIANCE BAG POLYETHYLENE HD PE 2 SORTED waste collection PLASTIC Check the instructions of the com petent body APPLIANCE BAG BAG OF ACCESSORIES BUBBLEWRAP PROTECTIVE SHEET LABELS PO...

Page 11: ...e chimney flue is efficient Switch on the stove at Power 5 for at least 2 hours in order to enable the materials which make up the boiler and the fireplace to adjust the inner springing stress After 2...

Page 12: ...ingmenutoincrease 5 Decreasesettemperature programmingfunctions 6 Increasesettemperature programmingfunctions 7 Display 8 Time 9 Status 10 Temperature setbyuser 11 Instantpower 12 Ambienttemperature 1...

Page 13: ...ith the keys select the language of interest IT EN DE FR ES NL PL DA SL Press menu to confirm and esc to exit b Cleaning To select Cleaning only when the boiler is switched off act as follows Press th...

Page 14: ...ress menu to confirm Scroll to Easy Set using the arrows Press menu to confirm With the keys select Easy Set of interest SET1 SET2 SET3 SET4 Press menu to confirm and esc to exit h Pellet Recipe To ch...

Page 15: ...pot is clean To start the stove keep the P1 button pressed until the ON sign and a flashing flame to its side appear The ignition resistance pre heatingstarts Aftersomesecondsthefeedscrewloadspellets...

Page 16: ...ettled Afterablack outofmorethan10seconds thestoveenterstheduringshutdown Completedthisphase itstartsautomatically up with the different phases 8 10 ADJUSTMENTS MENU To access the adjustments menu act...

Page 17: ...ngerperiod Theflamesetgoestotheminimumvalueautomaticallywhenthesettemperaturevalueisreached If only one notch appears the stove has a flame power equal to 1 If 5 notches appear the stove has a flame p...

Page 18: ...ave any effect while OFF will switch it off In the boiler on and timer active condition press the OFF key and the boiler will switch off it will switch on automatically at the next time set on the tim...

Page 19: ...13 Proper operation of a stove mainly depends on the flue it is connected to Once it is connected it is equally important to perform proper adjustment of combustion parameters The Easy Set feature ma...

Page 20: ...ase with respect to the default setting 15 15 increase with respect to the default setting 8 18 SMOKE RPM VARIATION SEE SECTION I SETTINGS MENU A PAG 13 Changestobemadewiththesupportoftheauthorisedtec...

Page 21: ...ctanAuthorized AssistanceService The main quality certifications for pellets currently available on the European market guarantee that the fuel complies with class A1 A2accordingtoISO17225 2 Thesecert...

Page 22: ...ading system stops when the tank door is opened Before closing the lid make sure there are no pellets below the gasket Pellets deteriorate the gasket and eliminateitsairtightsealing vediFig 25 10 VENT...

Page 23: ...haust Significant negative wind clogged fume passages open pellet loading tank open fire door or worn broken gaskets see SMOKE RPMVARIATION User Manual 12 2 SMOKE TEMPERATURE PROBE Detects the tempera...

Page 24: ...E OF PROBLEM SOLUTION A01 The fire does not ignite Check whether the brazier is clean level of pellets in the hopper Check pellet level in the tank Check that the burning pot is correctly positioned i...

Page 25: ...erationsmustbeplannedintimewithyourAutorizedTechnicalAssistanceService After a long ineffective time before turning on the stove check if there are obstructions in the fume exhaust If the stove had be...

Page 26: ...example put on a wooden floor as the inner ash keeps the embers firing for a long time Only when the embers are off the ash coul be poured in the organic waste Pay attention if the flame becomes red...

Page 27: ...s ceramic of the fire door is able to stand till 700 C but not to thermal shocks The probable cleaning with usual sale product for glass cleaning must be effected at cool glass in order to avoid explo...

Page 28: ...tareessential for the correct operation of the product is provided below USER TECHNICIAN PARTS FREQUENCY 1 DAY 2 3 DAYS 7 DAYS 1YEAR UNDERTHE USER S RESPONSIBILITY Brazier X Ash compartment X Glass X...

Page 29: ...en fire door or open pellet door Close fire door and pellet door and check that there are no pellet grains at the gasket level Clogged stove Fume chamber cleaning Auger blocked by a foreign object for...

Page 30: ...d Faulty fume tempe rature probe Replace the fume probe Faulty mother board Replace the mother board Ash remains along the stove Faulty or out of order door gaskets Replace the gaskets Not sealed fume...

Page 31: ...133 mg Nm3 Heat output Nominal heat output Pnom 8 5 kW Minimum heat output indicative Pmin 3 3 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 89 Useful efficiency...

Page 32: ...Heat output Nominal heat output Pnom 7 4 kW Minimum heat output indicative Pmin 3 3 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 90 Useful efficiency at minimu...

Page 33: ...NOTE...

Page 34: ...NOTE...

Page 35: ...NOTE...

Page 36: ...www cadelsrl com www free point it www pegasoheating com CADEL srl 31025 S Lucia di Piave TV Via Martiri della Libert 74 Italy Tel 39 0438 1520200 Rev 00 2023...