12.6  GEAR MOTOR

If the gear motor stops, the boiler will continue to run until the flame goes out due to lack of fuel and until a minimum level of 

cooling is reached.

12.7  TEMPORARY POWER CUT

If the power cut lasts less than 10” the boiler returns to its previous operating status; if it lasts more it carries out a cooling/restart 

cycle.

12.8  FAILED START-UP

If during ignition no flame develops, the boiler will go into alarm condition.

12.9  BLACKOUT WITH THE BOILER ON

In the event of a power cut (BLACKOUT) the boiler behaves as follows:

•  Blackout below 10”: it returns to its operation in progress;

•  In the event of a power cut that lasts over 10” with the boiler on or in the start-up stage, when the boiler is powered again it 

goes back to the previous operating condition with the following procedure:

1)  It performs a cooling phase to the maximum.
2)  Performs a new ignition.

During stage 1 the panel displays ON BLACK OUT.

During stage 2 the panel displays Start-up.

If during stage 1 the boiler receives commands from the panel and thus carried out manually by the user, then the boiler stops 

executing the blackout recovery status and proceeds to restart or shutdown as requested by the command.

12.10  ALARM ALERTS

Whenever an operating condition other than that designed for the regular operation of the boiler occurs, there is an alarm condi-

tion.

The control panel gives information on the reason of the alarm in progress.

PANEL ALERT

TYPE OF PROBLEM

SOLUTION

A01

The fire does not ignite.

Check whether the brazier is clean / level of pellets in the 

hopper.

Check pellet level in the tank. 

Check  that  the  burning pot  is  correctly  positioned in its 

case and does not contain deposits or unburned material. 

Check that the pellet cover and the fire door are correctly 

closed.

Clogged flue

Damaged ignition resistance 

A02

The fire goes off abnormally.

Check the level of pellets in the hopper.

A03 Thermostat 

alarms

The temperature of the pellets hopper or the 

water temperature exceed the envisioned safety 

threshold.

Wait for the cooling stage to end, cancel the alarm and 

restart the boiler setting the fuel loading at minimum 

(SETTINGS menu - Pellet Recipe).

Check that dust does not clog the aeration grid on the stove 

back.

If the alarm persists, contact the service centre. Check if the 

room fan works properly (if present).

A04

Smoke overheating.

The set smoke threshold has been exceeded. Reduce pellets 

loading (SETTINGS menu - Pellet Recipe).

A05 Pressure 

switches alarm

Flue gas pressure switch trip.  (see SMOKE RPM 

VARIATION User Manual)

Check for chimney obstructions/fire door opening, pellet 

tank opening, gasket seals, side fire ducts cleaning, clogged 

hose connection, excess flue length, unfavourable weather 

conditions and clogged stove.

A08

Abnormal smoke fan operation.

If the alarm persists, contact the service centre.

A09

Smoke probe faulty.

If the alarm persists, contact the service centre.

SERVICE

Routine maintenance alert (it does not block the 

system).

When this flashing message appears upon start-up, it 

means that the preset operating hours have elapsed before 

maintenance. Contact the service centre.

Summary of Contents for ARCO 7 T1 BI-FLUX

Page 1: ...EN USER MANUAL Pellet Stove 2023CADELsrl Allrightsreserved Tuttiidirittiriservati new ARCO 7 T1 ARCO 7 T1 BI FLUX ARCO 9 T2 ARCO 9 T2 BI FLUX ELLE PLUS 9 T2 LUCE PLUS 9 T2...

Page 2: ...ONXSETTINGSMENU A PAG 13 19 8 17 PELLETS RECIPE SEE SECTION H SETTINGS MENU A PAG 13 20 8 18 SMOKE RPM VARIATION SEE SECTION I SETTINGS MENU A PAG 13 20 8 19 CHIMNEY SWEEP FUNCTION FOR MAINTENANCE TEC...

Page 3: ...includingthosereferringtonationalandEuropeanstandards mustbeobservedwheninstallingtheappliance In Italy for the installation of systems with a biomass below 35KW refer to the Ministerial Decree 37 08...

Page 4: ...these operating conditions increase the risk of premature wear of the product especially those parts exposed to the direct heat of the fire e g combustion chamber theoriginalconditionofwhichcanunderg...

Page 5: ...protector made of in combustiblematerial steel glass etc thatalsoprotectsthefrontpartfromanyfallingburnt particles during cleaning The electrical cable must not get in touch with the fume exhaust pip...

Page 6: ...ly check and empty the inspectionable parts of the smoke duct e g Tee fitting caps Have the smoke outlet system periodically checked and cleaned The product is not a cooking appliance Always keep the...

Page 7: ...Damage caused during transportation or relocation All parts that develop faults due to negligence or improper use incorrect maintenance installation that does not comply with the manufacturer s instru...

Page 8: ...e sole party responsible for demolishing and disposing of the product This must be performed in compliance with laws related to safety and environmental protection in force in his her country At the e...

Page 9: ...2 Wastedisposal Thissymbol whichisusedontheproduct batteries accumulatorsoronthepackagingordocuments meansthatattheendofits useful life this product the batteries and the accumulators included must no...

Page 10: ...com petent body APPLIANCE BAG POLYETHYLENE HD PE 2 SORTED waste collection PLASTIC Check the instructions of the com petent body APPLIANCE BAG BAG OF ACCESSORIES BUBBLEWRAP PROTECTIVE SHEET LABELS PO...

Page 11: ...e chimney flue is efficient Switch on the stove at Power 5 for at least 2 hours in order to enable the materials which make up the boiler and the fireplace to adjust the inner springing stress After 2...

Page 12: ...ingmenutoincrease 5 Decreasesettemperature programmingfunctions 6 Increasesettemperature programmingfunctions 7 Display 8 Time 9 Status 10 Temperature setbyuser 11 Instantpower 12 Ambienttemperature 1...

Page 13: ...ith the keys select the language of interest IT EN DE FR ES NL PL DA SL Press menu to confirm and esc to exit b Cleaning To select Cleaning only when the boiler is switched off act as follows Press th...

Page 14: ...ress menu to confirm Scroll to Easy Set using the arrows Press menu to confirm With the keys select Easy Set of interest SET1 SET2 SET3 SET4 Press menu to confirm and esc to exit h Pellet Recipe To ch...

Page 15: ...pot is clean To start the stove keep the P1 button pressed until the ON sign and a flashing flame to its side appear The ignition resistance pre heatingstarts Aftersomesecondsthefeedscrewloadspellets...

Page 16: ...ettled Afterablack outofmorethan10seconds thestoveenterstheduringshutdown Completedthisphase itstartsautomatically up with the different phases 8 10 ADJUSTMENTS MENU To access the adjustments menu act...

Page 17: ...ngerperiod Theflamesetgoestotheminimumvalueautomaticallywhenthesettemperaturevalueisreached If only one notch appears the stove has a flame power equal to 1 If 5 notches appear the stove has a flame p...

Page 18: ...ave any effect while OFF will switch it off In the boiler on and timer active condition press the OFF key and the boiler will switch off it will switch on automatically at the next time set on the tim...

Page 19: ...13 Proper operation of a stove mainly depends on the flue it is connected to Once it is connected it is equally important to perform proper adjustment of combustion parameters The Easy Set feature ma...

Page 20: ...ase with respect to the default setting 15 15 increase with respect to the default setting 8 18 SMOKE RPM VARIATION SEE SECTION I SETTINGS MENU A PAG 13 Changestobemadewiththesupportoftheauthorisedtec...

Page 21: ...ctanAuthorized AssistanceService The main quality certifications for pellets currently available on the European market guarantee that the fuel complies with class A1 A2accordingtoISO17225 2 Thesecert...

Page 22: ...ading system stops when the tank door is opened Before closing the lid make sure there are no pellets below the gasket Pellets deteriorate the gasket and eliminateitsairtightsealing vediFig 25 10 VENT...

Page 23: ...haust Significant negative wind clogged fume passages open pellet loading tank open fire door or worn broken gaskets see SMOKE RPMVARIATION User Manual 12 2 SMOKE TEMPERATURE PROBE Detects the tempera...

Page 24: ...E OF PROBLEM SOLUTION A01 The fire does not ignite Check whether the brazier is clean level of pellets in the hopper Check pellet level in the tank Check that the burning pot is correctly positioned i...

Page 25: ...erationsmustbeplannedintimewithyourAutorizedTechnicalAssistanceService After a long ineffective time before turning on the stove check if there are obstructions in the fume exhaust If the stove had be...

Page 26: ...example put on a wooden floor as the inner ash keeps the embers firing for a long time Only when the embers are off the ash coul be poured in the organic waste Pay attention if the flame becomes red...

Page 27: ...s ceramic of the fire door is able to stand till 700 C but not to thermal shocks The probable cleaning with usual sale product for glass cleaning must be effected at cool glass in order to avoid explo...

Page 28: ...tareessential for the correct operation of the product is provided below USER TECHNICIAN PARTS FREQUENCY 1 DAY 2 3 DAYS 7 DAYS 1YEAR UNDERTHE USER S RESPONSIBILITY Brazier X Ash compartment X Glass X...

Page 29: ...en fire door or open pellet door Close fire door and pellet door and check that there are no pellet grains at the gasket level Clogged stove Fume chamber cleaning Auger blocked by a foreign object for...

Page 30: ...d Faulty fume tempe rature probe Replace the fume probe Faulty mother board Replace the mother board Ash remains along the stove Faulty or out of order door gaskets Replace the gaskets Not sealed fume...

Page 31: ...133 mg Nm3 Heat output Nominal heat output Pnom 8 5 kW Minimum heat output indicative Pmin 3 3 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 89 Useful efficiency...

Page 32: ...Heat output Nominal heat output Pnom 7 4 kW Minimum heat output indicative Pmin 3 3 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 90 Useful efficiency at minimu...

Page 33: ...NOTE...

Page 34: ...NOTE...

Page 35: ...NOTE...

Page 36: ...www cadelsrl com www free point it www pegasoheating com CADEL srl 31025 S Lucia di Piave TV Via Martiri della Libert 74 Italy Tel 39 0438 1520200 Rev 00 2023...

Reviews: