background image

5

LUCE   -  ELLE  -  ARCO 

 

 SAFETY REQUIREMENTS 

 

 

 

•  Installation, electrical connection, functional verification and maintenance must only be 

performed by qualified or authorised personnel.

•  Live electrical parts: disconnect the product from the 230V power supply before perfor-

ming any maintenance operation. Only power the product after completing assembly.

•  Special maintenance must only be performed by authorised and qualified personnel.

•  All local regulations, including those referring to national European standards, must be 

respected during appliance installation.

•  The manufacturer declines any responsibility in case of installation which are not in compliance 

with current regulations, in case of a wrong room ventilation system, in case of an electric connec-

tion which is not in compliance with regulations and in case of a wrong use of the appliance.

•  It is forbidden to install the stove in bedrooms, bathrooms and in rooms used for storing 

combustible materials and in one-room flats.

•  The installation in one-room flats is allowed if they are in sealed chamber.

•  In any case the stove must not be installed in rooms where it can get in touch with water or 

water splashes because this can cause burn hazards and short-circuit.

•  Please check that the floor has an adequate load capacity. If the existing one does not 

satisfy this requirement, appropriate measure should be provided (for example a plate for di-

stributing the load).

•  For safety fire regulations the distances  from flammable or sensible to heat objects (sofas, 

pieces of furniture, wooden covering, etc...) must be respected.

•  If there are highly flammable objects (curtains, fitted carpet, etc...), all these distances 

must be further increased with 1 meter.

•  If the floor is made of combustible material, we recommend using a protector made of in-

combustible material (steel, glass, etc.) that also protects the front part from any falling burnt 

particles during cleaning.

•  The electrical cable must not get in touch with the fume exhaust pipe and nor with every 

other part of the stove.

•  The user, or whoever is operating the product, must read and fully understand the contents 

of this installation and use guide before performing any operation. Errors or incorrect settings 

can cause hazardous conditions and/or poor operation.

•  The type of fuel to use is only the pellets.

•  Do not use the appliance as waste inceneretor.

•  Do not place laundry on the product to dry. Any clothes horses or similar objects must be 

kept at a safe distance from the product. Fire hazard.

•  It is forbidden to operate the product with the door open or the glass broken.

•  It is forbidden to modify the appliance without authorization. 

•  Do not use flammable liquids during the ignition (alcool, petrol, oil, etc...).

•  After a failed ignition the burning pot must be empty from the amassed pellets, before 

starting the stove up again.

•  The pellet hopper must always be closed with its own lid. 

•  Before of every intervention leave the fire completely extinguish till the cooling and always 

disconnect the plug from the electric socket.

•  This appliance can be used by children aged from 8 years and above and persons with re-

duced physical, sensory or mental capabilities or lack of experience and knowledge if they 

have been given supervision or instruction concerning use of the appliance in a safe way and 

understand the hazards involved. Children shall not play with the appliance. Cleaning and 

user maintenance shall not be made by children without supervision.

•  Packaging are not toys and could cause suffocation or strangulation and other health ha-

zards! People (childreen included) with reduced mobility, psycological deseases or without 

experience and knowledge must be kept away from packaging. The stove 

IS NOT 

a toy.

Summary of Contents for ARCO 7 T1 BI-FLUX

Page 1: ...EN USER MANUAL Pellet Stove 2023CADELsrl Allrightsreserved Tuttiidirittiriservati new ARCO 7 T1 ARCO 7 T1 BI FLUX ARCO 9 T2 ARCO 9 T2 BI FLUX ELLE PLUS 9 T2 LUCE PLUS 9 T2...

Page 2: ...ONXSETTINGSMENU A PAG 13 19 8 17 PELLETS RECIPE SEE SECTION H SETTINGS MENU A PAG 13 20 8 18 SMOKE RPM VARIATION SEE SECTION I SETTINGS MENU A PAG 13 20 8 19 CHIMNEY SWEEP FUNCTION FOR MAINTENANCE TEC...

Page 3: ...includingthosereferringtonationalandEuropeanstandards mustbeobservedwheninstallingtheappliance In Italy for the installation of systems with a biomass below 35KW refer to the Ministerial Decree 37 08...

Page 4: ...these operating conditions increase the risk of premature wear of the product especially those parts exposed to the direct heat of the fire e g combustion chamber theoriginalconditionofwhichcanunderg...

Page 5: ...protector made of in combustiblematerial steel glass etc thatalsoprotectsthefrontpartfromanyfallingburnt particles during cleaning The electrical cable must not get in touch with the fume exhaust pip...

Page 6: ...ly check and empty the inspectionable parts of the smoke duct e g Tee fitting caps Have the smoke outlet system periodically checked and cleaned The product is not a cooking appliance Always keep the...

Page 7: ...Damage caused during transportation or relocation All parts that develop faults due to negligence or improper use incorrect maintenance installation that does not comply with the manufacturer s instru...

Page 8: ...e sole party responsible for demolishing and disposing of the product This must be performed in compliance with laws related to safety and environmental protection in force in his her country At the e...

Page 9: ...2 Wastedisposal Thissymbol whichisusedontheproduct batteries accumulatorsoronthepackagingordocuments meansthatattheendofits useful life this product the batteries and the accumulators included must no...

Page 10: ...com petent body APPLIANCE BAG POLYETHYLENE HD PE 2 SORTED waste collection PLASTIC Check the instructions of the com petent body APPLIANCE BAG BAG OF ACCESSORIES BUBBLEWRAP PROTECTIVE SHEET LABELS PO...

Page 11: ...e chimney flue is efficient Switch on the stove at Power 5 for at least 2 hours in order to enable the materials which make up the boiler and the fireplace to adjust the inner springing stress After 2...

Page 12: ...ingmenutoincrease 5 Decreasesettemperature programmingfunctions 6 Increasesettemperature programmingfunctions 7 Display 8 Time 9 Status 10 Temperature setbyuser 11 Instantpower 12 Ambienttemperature 1...

Page 13: ...ith the keys select the language of interest IT EN DE FR ES NL PL DA SL Press menu to confirm and esc to exit b Cleaning To select Cleaning only when the boiler is switched off act as follows Press th...

Page 14: ...ress menu to confirm Scroll to Easy Set using the arrows Press menu to confirm With the keys select Easy Set of interest SET1 SET2 SET3 SET4 Press menu to confirm and esc to exit h Pellet Recipe To ch...

Page 15: ...pot is clean To start the stove keep the P1 button pressed until the ON sign and a flashing flame to its side appear The ignition resistance pre heatingstarts Aftersomesecondsthefeedscrewloadspellets...

Page 16: ...ettled Afterablack outofmorethan10seconds thestoveenterstheduringshutdown Completedthisphase itstartsautomatically up with the different phases 8 10 ADJUSTMENTS MENU To access the adjustments menu act...

Page 17: ...ngerperiod Theflamesetgoestotheminimumvalueautomaticallywhenthesettemperaturevalueisreached If only one notch appears the stove has a flame power equal to 1 If 5 notches appear the stove has a flame p...

Page 18: ...ave any effect while OFF will switch it off In the boiler on and timer active condition press the OFF key and the boiler will switch off it will switch on automatically at the next time set on the tim...

Page 19: ...13 Proper operation of a stove mainly depends on the flue it is connected to Once it is connected it is equally important to perform proper adjustment of combustion parameters The Easy Set feature ma...

Page 20: ...ase with respect to the default setting 15 15 increase with respect to the default setting 8 18 SMOKE RPM VARIATION SEE SECTION I SETTINGS MENU A PAG 13 Changestobemadewiththesupportoftheauthorisedtec...

Page 21: ...ctanAuthorized AssistanceService The main quality certifications for pellets currently available on the European market guarantee that the fuel complies with class A1 A2accordingtoISO17225 2 Thesecert...

Page 22: ...ading system stops when the tank door is opened Before closing the lid make sure there are no pellets below the gasket Pellets deteriorate the gasket and eliminateitsairtightsealing vediFig 25 10 VENT...

Page 23: ...haust Significant negative wind clogged fume passages open pellet loading tank open fire door or worn broken gaskets see SMOKE RPMVARIATION User Manual 12 2 SMOKE TEMPERATURE PROBE Detects the tempera...

Page 24: ...E OF PROBLEM SOLUTION A01 The fire does not ignite Check whether the brazier is clean level of pellets in the hopper Check pellet level in the tank Check that the burning pot is correctly positioned i...

Page 25: ...erationsmustbeplannedintimewithyourAutorizedTechnicalAssistanceService After a long ineffective time before turning on the stove check if there are obstructions in the fume exhaust If the stove had be...

Page 26: ...example put on a wooden floor as the inner ash keeps the embers firing for a long time Only when the embers are off the ash coul be poured in the organic waste Pay attention if the flame becomes red...

Page 27: ...s ceramic of the fire door is able to stand till 700 C but not to thermal shocks The probable cleaning with usual sale product for glass cleaning must be effected at cool glass in order to avoid explo...

Page 28: ...tareessential for the correct operation of the product is provided below USER TECHNICIAN PARTS FREQUENCY 1 DAY 2 3 DAYS 7 DAYS 1YEAR UNDERTHE USER S RESPONSIBILITY Brazier X Ash compartment X Glass X...

Page 29: ...en fire door or open pellet door Close fire door and pellet door and check that there are no pellet grains at the gasket level Clogged stove Fume chamber cleaning Auger blocked by a foreign object for...

Page 30: ...d Faulty fume tempe rature probe Replace the fume probe Faulty mother board Replace the mother board Ash remains along the stove Faulty or out of order door gaskets Replace the gaskets Not sealed fume...

Page 31: ...133 mg Nm3 Heat output Nominal heat output Pnom 8 5 kW Minimum heat output indicative Pmin 3 3 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 89 Useful efficiency...

Page 32: ...Heat output Nominal heat output Pnom 7 4 kW Minimum heat output indicative Pmin 3 3 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 90 Useful efficiency at minimu...

Page 33: ...NOTE...

Page 34: ...NOTE...

Page 35: ...NOTE...

Page 36: ...www cadelsrl com www free point it www pegasoheating com CADEL srl 31025 S Lucia di Piave TV Via Martiri della Libert 74 Italy Tel 39 0438 1520200 Rev 00 2023...

Reviews: