ATENA3 PLUS 12/14 - DUKE 12/14 AIRTIGHT - SABA 12/14 - MITHOS3 PLUS 12/14
12
Fig. 12 - Phase1
• Connect the air intake pipe to the combustion air pipe of the stove and tighten everything with a clamp (see [
Fig. 12
).
5
INSTALLATION
5.1
INTRODUCTION
• The assembly position must be chosen depending on environment, outlet, chimney flue.
• Check with local authorities if there are any restrictive regulations which regard the combustible air inlet, room ventilation,
fume exhaust system together with chimney flue and chimney pot.
• Check if there is the combustible air inlet.
• Check the probable presence of other stoves or appliances which could depress the room.
• Check at switched on stove if there is the presence of CO in the room.
• Check if the chimney has the necessary draught.
• Check if during the fume passage all has been executed in safety (probable fume losses and distances from flammable mate-
rials, etc.…).
• The installation of the appliance must enable an easy access for appliance, fume exhaust pipes and chimney flue cleaning.
• The installation must enable en easy access to the electric connection plug (see
ELECTRIC CONNECTION a pag. 28
).
• To install more appliances, the external air inlet must be correctly dimensioned (see
FEATURES a pag. 37
).
5.2
OVERALL DIMENSIONS
Fig. 13 - General dimensions: Atena
3
Plus 12/14
LEGEND
Fig. 13
A
Exhaust fumes d.8 cm
B
Hole combustion air inlet d.6 cm
C
Ducting outlet d.8 cm