31
ATENA3 PLUS 12/14 - DUKE 12/14 AIRTIGHT - SABA 12/14 - MITHOS3 PLUS 12/14
6.3
FUME PASSAGE CLEANING
Every end-of-season (or every 2000 hours of operation) it is necessary to clean the fume passages.
• Remove the door (see the dedicated chapter).
• Undo the screws of the door deflector (see
Fig. 96
) and remove it.
• Undo the hex head screws that block the cast-iron tiles of the hearth, on both sides (see
Fig. 97
).
• Push the head of the firebox up (see
Fig. 98
), tilt the piece and pull it out (see
Fig. 99
).
Fig. 96 - Remove the deflector
Fig. 97 - Remove the hex screws
Fig. 98 - Remove the head of the firebox 1
• Then remove the side walls of the firebox (see
Fig. 100
).
• Lastly remove the back panel of the firebox (see
Fig. 101
).
Fig. 99 - Remove the head of the firebox 2
Fig. 100 - Remove the side walls
Fig. 101 - Remove the back panel of the firebox
• Clean with a pipe cleaner and suction any ash accumulated inside (see
Fig. 102
).
• Part of the ash will fall into the compartment below the firebox (see
Fig. 103
). See the previous chapter for the cleaning
operation.
Fig. 102 - Clean with pipe cleaner
Fig. 103 - Vacuum out the ash