6.4
FUME FAN CLEANING
Clean every the year the fume fan from ash or dust which can cause a blade unbalance and a greater noise.
• Open the door and release the panel under the door (see dedicated chapter).
• Remove the inspection cap (see
Fig. 104
).
• Unscrew the 2 screws of the smoke deflector inside (see
Fig. 105
) and remove it (see
Fig. 106
).
Fig. 104 - Remove the cap
Fig. 105 - Unscrew the screws
Fig. 106 - Remove the fume diverter
• Vacuum the blades of the fume extraction fan (see
Fig. 107
).
• After cleaning, repeat the operation in reverse making sure the gasket is intact and efficient: if necessary, have it replaced by
an authorised technician.
Fig. 107 - Vacuum out the ash
6.5
ROOM FAN CLEANING
Clean every the year the room fan from ash or dust which can cause a blade unbalance and a greater noise.
Fig. 108 - Room fan cleaning (Atena
3
Plus 12/14 - Duke 12/14 At - Saba
12/14)
Fig. 109 - Room fan cleaning (Mithos
3
Plus 12/14)