ATENA3 PLUS 12/14 - DUKE 12/14 AIRTIGHT - SABA 12/14 - MITHOS3 PLUS 12/14
36
PROBLEM
CAUSE
SOLUTION
INTERVENTION
Stove running and
display showing
"SERVICE"
Routine main-
tenance alert (it
does not block the
system)
When this flashing message appears upon start-up, it means
that the preset operating hours have elapsed before mainte-
nance. Contact the service centre.
“Pellet reserve
enabling” activates
with the tank full
Failure to reach the
threshold tem-
perature, large or
poor quality pellet,
clogged fume
passage
Increase pellet with “Pellet Recipe” or clean the combustion
chamber
8
TECHNICAL DATAS
8.1
REPAIR INFORMATION
Now we give some instructions for the Authorized Technician to take into consideration to have access to stove mechanical com-
ponents.
• For fuse replacement in the electric socket which stands on the back of the stove, extract the fuses to change with the aid of a
screwdriver for opening the shutter (see
Fig. 110
).
Fig. 110 - Shutter with fuses to remove
Proceed as follows:
• Remove the frame (see the dedicated chapters).
• After these operations you can have access at the following components: geared motor, ignition plug, ambient fan, fume fan,
ambient probe, fume probe, thermostat, electronic board, pressostat.
• For cleaning or replacemente of the auger it is necessary to unscrew the three bolt of the geared motor and to extract it, un-
screw the two screws lying under the geared motor (vedi
Fig. 111
), of the auger, remove the hand rejector inside the hopper
and then unscrew the inner bolt of the auger. (vedi
Fig. 112
).To assembly proceed at the contrary.
Fig. 111 - Remove the screws
Fig. 112 - Remove the screw