29
CRISTAL 9 - LIFE 9 - CRISTAL PLUS 9 - ICON PLUS 9 - STEEL 9
13.9 GASKET REPLACEMENT
In case of deterioration of fire door, hopper or fume chamber gaskets, it is necessary to replace them by an autorized technician in
order to guarantee the good running of the stove.
Use exclusively original spare parts.
13.10 GLASS CLEANING
The glass-ceramic of the fire door is able to stand till 700°C but not to thermal shocks.
The probable cleaning with usual sale product for glass cleaning must be effected at cool glass in order to avoid explosions.
You should clean the fire door glass every day!
13.11 SHUTDOWN (END OF SEASON)
At the end of each season, before switching the product off, it is recommended to remove all the pellets from the hopper with a
vacuum cleaner with a long pipe.
We recommend removing the unused pellets from the hopper because they can retain moisture. Disconnect any combustion air
ducting that can lead to moisture inside the combustion chamber but, above all, ask the specialised technician to refresh the paint
inside the combustion chamber with the special silicone spray paints (available at any store or Technical Assistance Centre) during
the necessary annual end of season scheduled maintenance operations. This way the paint will protect the inner parts of the com-
bustion chamber, blocking any type of oxidative process.
Fig. 37 - Shutter with fuses to remove
When not in use the appliance must be disconnected from the mains power supply. It is recommended to remove
the power cable for additional safety, especially in the presence of children.
The service fuse may have to be replaced if the control panel display does not switch on.
There is a fusebox on the back of the product, near the power socket.
After removing the plugs from the power socket, open the fusebox cover with a screwdriver and replace the fuses if necessary (3.15
A delayed) - seek assistance from an authorised and qualified technician.
13.12 CHECKING THE INNER COMPONENTS
ATTENTION!
The internal electromechanical components must only be checked by qualified personnel
whose technical expertise includes combustion and electricity.
We recommend for this yearly maintenance to be carried out (with a scheduled service contract). This operation consists of a visual
and functional inspection of the internal components. A summary of the checks and/or maintenance operations that are essential
for the correct operation of the product is provided below.
Summary of Contents for CRISTAL 9
Page 35: ...NOTE ...