LEGEND
4
Shield grid
5
Curve inlet to turn downwards
Check
if the purchased stove has a sealed-chamber. If the stove is endowed with a sealed-
chamber and you want also the whole installation with sealed chamber, please read the following instructions:
• It is necessary to extract the air for combustion directly from outside.
• Use a tube with minimum Ø60 mm and maximum 2 meters lenght; to connect see the back of the stove.
• French standards require installation in double-walled flues (concentric system). The combustion air is drawn
from the cavity.
• During installation step is necessary to verify the minimum distances required for the combustible air inlet as
(for example) an open door or window causes a vortex which could remove the combustible air necessary
to the stove (see the underlying scheme).
• On the external wall it is necessary to install a curve at 90° to protect the combustible air inflow from wind
effects: turn the curve inlet downwards, see
.
• Endow the curve with an external shield grid against birds in such a way that it cannot be obstructed by any
object.
Check with your local authorities if exists any restrictive regulation regarding the combustible
air inlet: if present, they must be applied
In some countries and/or regions the installation with sealed-chamber is obligatory: in case
of doubt, please follow the most restrictive regulations.
How to connect to the stove in the sealed chamber with concentric system:
Fig. 9 - Phase1
Fig. 10 - Phase 2
Fig. 11 - Phase 3
• Original position with completely embedded tube (see
).
• Pull out the tube for 2 cm (see
).
• Insert the female tube ø 6 cm (see
9.10
CHIMNEY FLUE CoNNECtIoN
Your pellet stove works through a fume draught forced by a fan. It is obligatory to check that all pipes are
realized in compliance with the following regulation on material selection: EN 1856-1, EN 1856-2 e UNI/TS 11278.
All must be effected by specialized personnel or companies as provided by UNI 10683:2012.
• The connection between the appliance and the chimney flue should be short in order to favor the draught
and to avoid condensation in the pipes.
• The fume conduit should be equivalent or longer than the outlet joint ones (Ø 80 mm).
• Some stove models are endowed with a lateral and/or back exhaust. Check that the unused exhaust is
sealed with the plug given with standard equipment.
sYstEM tYpE
Ø80 mm pIpE
Ø100 mm pIpE
Minimum vertical length
1,5 mt
2 mt
Maximum length (with 1 union)
6,5 mt
10 mt
Maximum length (with 3 unions)
4,5 mt
8 mt
Maximum number of unions
3
3
Level section (minimum inclination 3%)
2 mt
2 mt
Installation at a height above 1200 m a.s.l.
NO
Obligatory