Fig. 73 - Loosen the top screw
Fig. 74 - Loosen the bottom screw
Fig. 75 - Remove side panels
• Clean the 2 pipes inside the combustion chamber (placed on the top) with a pipe cleaner (see
,
• Loosen the two screws from the galvanised panel closing the flue gas compartment, which is found on both
).
• Clean with a pipe cleaner and suction any ash accumulated inside (see
• After the cleaning the opposite operation is to repeat checking the gasket efficiency and integrity: if necessary
provide for its replacement by an Authorized Technician.
Fig. 76 - Fume passages
Fig. 77 - Cleaning with a brush 1
Fig. 78 - Clean both the ducts
Fig. 79 - Fume chamber
Fig. 80 - Cleaning with a brush 2
Fig. 81 - Fume chamber cleaning
14.5
FUME CoNDUIt CLEANING
The exhaust system must be cleaned every season (or every 1500 operation hours).