Fig. 82 - Fume conduit cleaning
Fig. 83 - Fume conduit (Sfera
3
Plus, Sfera
3
, Globe, Elise
3
Plus)
• Remove the side panel as described in
FUME CHAMBER AND FUME pAssAGEs CLEANING page 33
.
• Remove the inspection lid of the T-union (see
).
• Extract the ash which has accumulated in the inner.
• After the cleaning repeate the opposite operation checking the integrity and eficiency of the gasket: if
necessary have it replaced by an Autorized Technician.
It is important to sealed the cap othrwise noxiuous fumes will propagate among the room.
14.6
FUME FAN CLEANING
Clean every the year the fume fan from ash or dust which can cause a blade unbalance and a greater noise.
Fig. 84 - Fume fan cleaning: phase1
Fig. 85 - Phase 2
Fig. 86 - Phase 3
• Follow the process as describer in
.
14.7
RooM FAN CLEANING
Clean every the year the room fan from ash or dust which can cause a blade unbalance and a greater noise.
Fig. 87 - Room fan cleaning