IN CAsE oF ANoMALY
15.1
ALARMs
Before of every testing and/or intervention by the Authorized Technician, the Authorized
Technician must check that the parameters of the mother board correspond to those of
the table you own.
In case of doubts regarding the stove running, please allways contact the Authorized
Technician in order to avoid irreparable damages.
ALARM
CAUsE
soLUtIoN
INtERvENtIoN
AL 1 - BLACK
OUT
Black out during ignition
step
Clean the fire pot and start the stove up again.
AL 2 - EXHAUST
PROBE
Disconnected fume
probe
Have the stove checked.
Faulty fume temperature
probe
Replace the fume probe.
AL 3 - HOT
EXHAUST
Faulty fume probe
Replace the fume probe.
Faulty mother board
Replace the mother board.
The ambient exchanger
fan does not work
Replace the ambient fan.
Pellet loading value too
high "stage 5"
Adjust pellet loading
AL 4 - FAN
FAILURE
Fume extractor out of
order
The pellet can burn also thank to chimney flue depression
without the aid of the extractor. Have the fume extractor
immediately replaced. It can be harmful to health to run
the stove without extractor.