7
FAMILY
EN
9.2
CHIMNEY FLUE
Fig. 1 - Chimney Flues
LEGEND
1
Chimney flue with insulated stainless-steel
pipes
2
Chimney flue on the existing chimney
3
Inspection plug
4
Inspection door
5
≥ 3,5 mt
•
The chimney flue or chimney is of great importance for the correct running of the heating appliance.
•
It is fundamental that the chimney flue is perfectly built and always maintained with a perfect efficiency.
•
The chimney flue must be sole (see
) with insulated stainless-steel pipes (1) or installed on the
existing chimney flue (2).
•
Both this solutions must be endowed with an inspection plug (3) and/or an inspection door (4).
9.3
TECHNICAL FEATURES
Fig. 2 - Inclined roof
LEGEND
1
Height over the ridge of the roof = 0,5 mt
2
Roof inclination ≥ 10°
3
90°
4
Measured distance at 90° from the roof surface = 1,3 mt
•
The chimney flue must be sealed from fumes.