34
FAMILY
EN
LEGEND
5
Geared motor
6
Fume fan
7
Probe fan
8
Inspection panel
9
Fume fan panel
10
Hand protection
To access the gear motor, auger, fumes exhaust and fumes probe:
•
Unplug and disconnect the fumes exhaust pipes.
•
Pull the stove out of its built-in position.
•
Loosen the 3 screws on the inspection panel + the 6 screws on the extractor cover (see
•
If you need to replace the auger, loosen the 2 screws on the hand protection plate.
17.2
FEATURES
DESCRIPTION
FAMILY 7,5 kW
WIDTH
60 cm
DEPTH
60 cm
HEIGHT
96 cm
WEIGHT
130 kg
INTRODUCED THERMIC POWER (Min/Max)
4,9 - 9,9 kW
NOMINAL THERMIC POWER (Min/Max)
3,5 - 7,5 kW
EFICIENCY (Min/Max)
71 - 76 %
FUME TEMPERATURE (Min/Max)
141 - 203 °C
FUME MAXIMUM LOADING CAPACITY (Min/Max)
11,6 - 13,9 g/s
CO EMISSIONS (13% O
2
) (Min/Max)
0,027 - 0,022 %
OGC EMISSIONS (13% O
2
)
-
NO
X
EMISSIONS (13% O
2
)
-
CO
2
EMISSIONS (Min/Max)
2,3 - 4,3 %
Medium CO CONTENTS at 13% O
2
(Min/Max)
337 - 275 mg/Nm
3
Medium POWDER CONTENTS at 13% O
2
(Max)
-
CHIMNEY DEPRESSION (Min/Max)
10 - 14
MINIMUM SAFETY DISTANCE from flammable materials
200 mm
ON SHARED CHIMNEY FLUE
NO
FUME OUTLET DIAMETER
Ø80 mm
COMBUSTIBLE
Pellet Ø6-7 mm
PELLETS HEATING VALUE
5 kWh/kg
PELLETS HUMIDITY
≤ 10%
HEATING VOLUME 18/20°C Coeff. 0,045 kW (Min/Max)
84 - 180 m
3
HOURLY CONSUMPTION (Min/Max)
0,95 - 2,00 kg/h
HOPPER CAPACITY
24 kg
RANGE (Min/Max)
16,8 - 8,0 h
SUPPLY
230 V - 50 Hz
POWER INPUT (Max)
330 W
INGNITER RESISTANCE POWER INPUT
300 W
MINIMUM EXTERNAL AIR INLET (last effective area)
80 cm
2
STOVE WITH SEALED CHAMBER
NO
EXTERNAL AIR INLET FOR SEALED CHAMBER
-