65
VENUS - GIOIA
EN
LEGEND
Fig. 12 page 64
1
Insulating material
2
Inspection plug
3
Minimum safety distance = 0,5 mt
•
External chimney flue entirely made up of insulated stainless steel pipes, i.e. with double wall of minimum
Ø120 mm: all must be firmly attached to the wall. For chimney against wind effects please (see
Fig. 5
page 59
).
• Ducting system through T-unions which enables an easy cleaning without disassembling the pipes.
We recommend to check with your chimney flue manufacturer the safety distances
which must be respected and the type of insulating material. The aforesaid regulations
are valid also for holes made on the wall (EN 13501 - EN 13063 - EN 1856 - EN 1806 - EN
15827).
8
FUEL
8.1
FUEL
• The type of fuel to use is only the pellets.
•
Use top-quality pellets because they have influence in the calorific value and in ash remains.
•
Pellets features are: dimension Ø6-7mm (D06 Class), maximum lenght 40 mm, calorific value 5kWh/
kg, humidity ≤ 10%, ash remains ≤ 0,7%, they must be correctly pressed and not much mealy, without
sizing agents, resins and other additives (it is advisable to use pellets in compliance with the regulation
EN14961-2 type ENplus-A1 ).
• Not adequate pellets cause a bad combustion, a frequent burning pot obstruction and exhaust conduits
obstruction. Further it decreases the calorific value, soils the glass and increases consumptions and ash
and unburnt granules quantity.
Humid pellets cause a bad combustion and running, so please assure you that they are
stored in dry places and far at least one meter from the stove and/or any other source
of heat.
• It is advisable to try different type of pellets available on the market and to choose that which gives the
best performance.
• The use of bad quality pellets can damage the stove so that the warranty and manufacturer liability fall.
• Do not use the appliance as waste inceneretor.
• On all our product are used high-quality materials such as stainless-steel, steel, cast iron, etc... These
materials, before being sold on the market, are tested in laboratory, but despite this on the components
which enable the pellets flow (auger) there could exist minimum differences in the material used, in
roughness and porosity, which could generate usual variations in fuel transportation (pellets), causing a
flame raising or drapping with a possible switching off at lower powers.
•
Depending on the type of pellets it could be necessary a parameters adjustment, please contact an
Authorized Assistance Service.
9
INSTALLATION
9.1
INTRODUCTION
•
The assembly position must be chosen depending on environment, outlet, chimney flue.
Summary of Contents for GIOIA
Page 2: ......
Page 49: ...49 VENUS GIOIA IT 14 3 RICAMBI Fig 60 Ricambi ...
Page 52: ...52 VENUS GIOIA IT 14 4 DICHIARAZIONE DI CONFORMITÀ Fig 61 Dichiarazione di Conformità ...
Page 98: ...98 VENUS GIOIA EN 14 3 SPARE PARTS Fig 60 Spare parts ...
Page 101: ...101 VENUS GIOIA EN 14 5 DECLARATION OF CONFORMITY Fig 61 Declaration of Conformity ...
Page 148: ...148 VENUS GIOIA FR 14 3 PIÈCES DÉTACHÉES Fig 60 Pièces détachées ...
Page 151: ...151 VENUS GIOIA FR 14 5 DÉCLARATION DE CONFORMITÉ Fig 61 Déclaration de Conformité ...
Page 197: ...197 VENUS GIOIA ES 14 3 REPUESTOS Fig 60 Repuestos ...
Page 200: ...200 VENUS GIOIA ES 14 5 DECLARACIÓN DE CONFORMEDAD Fig 61 Declaración de conformedad ...
Page 247: ...247 VENUS GIOIA NL 14 3 RESERVEONDERDELEN Fig 60 Reserveinderdelen ...
Page 250: ...250 VENUS GIOIA NL 14 5 CONFORMITEITSVERKLARING Fig 61 Conformiteitsverklaring ...
Page 297: ...297 VENUS GIOIA PT 14 3 PEÇAS SOBRESSALENTES Fig 60 Peças sobressalentes ...
Page 300: ...300 VENUS GIOIA PT 14 5 DECLARAÇÃO DE CONFORMIDADE Fig 61 Declaração de conformidade ...
Page 348: ...348 VENUS GIOIA EL 14 3 ΕΞΑΡΤΗΜΑΤΑ Fig 60 Εξαρτήματα ...
Page 351: ...351 VENUS GIOIA EL 14 5 ΔΗΛΩΣΗ ΣΥΜΜΟΡΦΩΣΗΣ Fig 61 Δηλωση Συμμορφωσησ ...