8.10 ADJUSTMENTS MENU
To access the adjustments menu act as follows:
•
Press the + - keys
•
Scroll with the <> arrows and select “Set Room T.” or “Air Fan Speed” or "Fire"
•
Press “menu” to access the selected option.
•
Modify with the + - keys.
•
Press “menu” to confirm and “esc” to exit.
Set Room T.
- this function allows setting the desired temperature in the room where the stove is installed, starting from a mi-
nimum of 5°C up to a maximum of 35°C. When this condition is met, the stove reaches the minimum consumption values (flame
and hot air fan speed at minimum values) and then goes back to the set values when the ambient temperature goes below the
set threshold (see
Fig. 6
).
Fig. 6 - Display
Note: The full stop to the right of the ambient temperature shown in the control panel display (upper right) indicates the half
degree (e.g. 23.° means 23.5°C).
Air Fan Speed
- this function allows selecting the desired speed for the ambient fans from 1 to 5 or A. A means automatic, venti-
lation depends on power, recommended setting (see
Fig. 7
).
A power 1 fans are off.
Fig. 7 - Display
Fire
- this function allows setting the flame power from a minimum of 1 to a maximum of 5. The power levels correspond to a different
fuel consumption value: by setting 5 you can heat the room in less time, while by setting 1 you can keep the ambient temperature
constant for a longer period. The flame set goes to the minimum value automatically when the set temperature value is reached.
If only one notch appears, the stove has a flame power equal to 1.
If 5 notches appear, the stove has a flame power equal to 5.
If the notches flash, automatic cleaning is under way.
Fig. 8 - Display
Fig. 9 - Power levels