IDRO PRINCE
3
12-16-23-23 H
2
O - IDRO PRINCE 30-30 H
2
O - AQUOS
3
16-23-23 H
2
O - IDRON 16-22 AIRTIGHT - MIRA 16-22 - TESIS 16-23 AIRTIGHT - HIDROFIRE 22.8
9
The poorer the quality of the fuel, the more often the internal parts of the brazier and combustion chamber
must be cleaned.
DINplus, Ö-Norm M7135 and Pellet gold are examples of the major quality certifications of pellets in the European market and
guarantee that the following are complied with:
• calorific value: 4.9 kWh/kg.
• Water content: max 10% of the weight.
• Percentage of ash: max 0.5% of the weight.
• Diameter: 5 – 6 mm.
• Length: max 30 mm.
• Content: 100% untreated wood with no added binding agents (max percentage of bark: 5%).
• Packaging: in bags made from environmentally friendly or biologically decomposable material.
The company strongly recommends using certified fuel for its products (DINplus, Ö-Norm M7135 or Pellet Gold).
Poor quality pellets or others that do not comply with that specified previously compromises the operation of
your product and can therefore render the warranty and product liability null and void.
3.3
FOREWORD
The assembly position must be chosen based on the room, the exhaust, the flue. Check with the local authorities whether there
are stricter provisions regarding the combustion air vent, the smoke exhaust system, including the flue and chimney cap. The ma-
nufacturer declines all liability in the event of installations that do not comply with the laws in force, improper local air exchange,
electrical connection that does not comply with the standards, and inappropriate use of the appliance. The installation must be
done by a qualified technician, who must issue the purchaser a declaration of conformity of the system and who will take on all
liability of the definitive installation and subsequent proper product operation.
In particular, he/she must make sure that:
• there is an appropriate combustion air vent and smoke exhaust compliant with the type of product installed
• other stoves or installed appliances do not create a vacuum in the room where the product is installed (15 Pa of vacuum maxi-
mum is allowed only for airtight appliances)
• smoke does not flow back into the room when the product is on
• smoke is extracted in complete safety (sizing, smoke seal, distance from flammable materials).
In particular, be sure to check the flue plate data for the safety distances that must be respected when there are
combustible materials and for the type of insulating material to use. These regulations must always be strictly
followed to prevent serious harm to human health and damage to the home.
The appliance must be installed so as to ensure easy access to clean it, the smoke exhaust pipes, and the flue.
Installing stoves in
rooms with a risk of fire is prohibited. Only airtight or closed appliances equipped with appropriate ducts to chan-
nel the combustion air directly to the outside can be installed in studio flats, bedrooms, and bathrooms. Always
keep an appropriate distance and protection in order to prevent the product from coming into contact with water.
Should several appliances be installed, the outside air vent must be sized accordingly.
3.4
MINIMUM DISTANCES
We recommend installing the stove away from any walls and/or furniture with minimum air circulation to efficiently ventilate
the appliance and properly distribute heat in the room. Respect the distances from flammable or heat-sensitive objects (sofas,
furniture, wood finishes, etc.), as specified below. The front distance from flammable materials must be at least the value shown
in the product technical data table.
For objects that are considered particularly delicate, like furniture, curtains, sofas, increase the distance from the stove accordingly.
If there are wood floors, we recommend assembling a floor protector and, in any case, following the standards
in force in the country.