IDRO PRINCE
3
12-16-23-23 H
2
O - IDRO PRINCE 30-30 H
2
O - AQUOS
3
16-23-23 H
2
O - IDRON 16-22 AIRTIGHT - MIRA 16-22 - TESIS 16-23 AIRTIGHT - HIDROFIRE 22.8
10
Fig. 2 - Safety distance
MODEL
NON-FLAMMABLE WALLS
FLAMMABLE WALLS
IDRO PRINCE
3
12
A = 5 cm / B = 5 cm
A = 20 cm / B = 20 cm
IDRO PRINCE
3
16-23-23 H2O
A = 5 cm / B = 5 cm
A = 20 cm / B = 20 cm
IDRO PRINCE 30-30 H2O
A = 5 cm / B = 5 cm
A = 20 cm / B = 20 cm
AQUOS
3
16-23-23 H2O
A = 5 cm / B = 5 cm
A = 20 cm / B = 20 cm
IDRON 16-22 AIRTIGHT
A = 5 cm / B = 5 cm
A = 20 cm / B = 20 cm
HIDROFIRE 22.8
A = 5 cm / B = 5 cm
A = 20 cm / B = 20 cm
If the floor is made of combustible material, we recommend using a protector made of incombustible material (steel, glass) that
also protects the front part from any falling burnt particles during cleaning.
The appliance must be installed on flooring that has an appropriate load-bearing capacity.
If the existing construction does not meet this requirement, appropriate measures must be taken (for example, a load distribution plate).
3.5
FOREWORD
This Flue chapter was written in reference to European standard requirements (EN 13384 - EN 1443 - EN 1856 - EN 1457).
It provides some instructions on how to properly install the flue but it does not in any way replace the standards in force, of which
the qualified manufacturer must be in possession. Check with the local authorities whether there are stricter standards regarding
the combustion air vent, the smoke exhaust system, the flue, the chimney cap.
The company declines all liability regarding poor stove operation if it can be attributed to using an incorrectly sized flue that does
not meet the standards in force.
3.6
FLUE
The flue or chimney is extremely important for forced draft heating appliances fired by solid fuels to work properly, as modern
heating appliances are high performing with cooler smoke and, as such, less draft. Thus, it is fundamental for the flue to be built
properly and always kept perfectly efficient. A flue serving a pellet/wood appliance must be at least category T400 (or above if
the appliance requires it) and resistant to soot fire. Smoke must be extracted via individual flue with insulated steel pipes (A) or
existing flue and must comply with the intended use (B).
A simple cement cavity must be appropriately ducted. Both solutions require an inspection cap (AT) and/or inspection door (AP) - FIG.1.
Do not connect more than one wood/pellet or other types (exhaust hood) of appliance (*) to the same flue.
(*) unless there are national exceptions (for example, in Germany), which allow more than one appliance to be installed in the same
chimney under opportune conditions; in any case, scrupulously follow the product/installation requisites provided for by the corre-
sponding standards/laws in force in the country