Fig. 11 - Solution 1 = directly from the outside
Fig. 12 - Solution 2 = indirectly from an adjacent room
LEGEND
A
Air vent
B
Room to ventilate
C
Increased space beneath the door
The air needed for combustion can be directly connected to the outside air vent with a pipe of at least Ø50 mm, at most 3 linear
metres long; every pipe elbow is to be considered equivalent to a linear metre. For the pipe coupling, see the back of the stove.
For stoves installed in studio flats, bedrooms, and bathrooms (where permitted), the combustion air must be connected to the out-
side. In particular, for airtight stoves, said connection must be airtight so as not to jeopardise the overall airtight feature of the system.
MIN.1,5 m
MIN.1,5 m
MIN.1,5 m
MIN.0,3 m
Fig. 13 - Example
DISTANCE (metres)
THE DISTANCE OF THE AIR VENT MUST BE:
1.5 m
BELOW
Doors, windows, smoke exhausts, gaps...
1.5 m
HORIZONTAL TO
Doors, windows, smoke exhausts, gaps...
0.3 m
ABOVE
Doors, windows, smoke exhausts, gaps...
1.5 m
AWAY FROM
Smoke exhausts