IDRO PRINCE
3
12-16-23-23 H
2
O - IDRO PRINCE 30-30 H
2
O - AQUOS
3
16-23-23 H
2
O - IDRON 16-22 AIRTIGHT - MIRA 16-22 - TESIS 16-23 AIRTIGHT - HIDROFIRE 22.8
64
Fig. 69 - Rubber spacer (Idro Prince
3
16-23-23 H2O, Aquos
3
16-23-23 H2O,
Idron 16-22 Airtight, Hidrofire 22.8)
Fig. 70 - Rubber spacer (Idro Prince
3
30-30 H2O)
14.10 CHECKING THE INNER COMPONENTS
ATTENTION!
Only qualified personnel with technical knowledge of combustion and electricity can check the inner electri-
cal-mechanical components.
We recommend this maintenance be done annually (with a scheduled service contract), which focuses on a visual and functional
check of the inner components. Below is a summary of the checks and/or service that are essential for proper product operation.
• Gear motor
• Smoke extraction fan
• Smoke probe
• Ignition spark plug
• Pellet/water automatically rearming thermostat
• Room/water probe
• Motherboard
• Panel-board protective fuses
• Wiring
PARTS/FREQUENCY
EVERY DAY EVERY WEEK
15 DAYS
60-90 DAYS EVERY SEASON
Brazier cleaning *
X
Ash compartment vacuum cleaning
X
Ash pan cleaning
X
Fire door and glass cleaning
X
Turbulator cleaning
X
Lower ash pan cleaning
X
Exhaust “T”-fitting cleaning (outside
the boiler)
X