32
KOOK 60 4.0 - KOOK 67 4.0 - KOOK 70 4.0 - KOOK 80 - KOOK 87 - KOOK 90 4.0
EN
13.20
HEART BREAK (KOOK 80 - KOOK 87 - KOOK 90 4.0)
Probable cast iron or refractory heart break are due to an excessive overheating caused by too much fuel or
by too much combustion air. Have the damaged elements immediately replaced in order to avoid feather
damages to the stove.
Fig. 83 -
Unscrew the profile
Fig. 84 -
Remove the profile
Fig. 85 - Remove the refractory material
•
Remove the cast iron/ceramic glass top.
•
Undo the screw of the profile that locks the refractory material in place (see
).
•
Remove the steel profile (see
•
Remove the broken refractory material and replace it (see
).
Use exclusively original spare parts.
13.21
REPLACING THE STAINLESS STEEL TOP
In the event of a replacement, proceed as follows:
Fig. 86 - Screw removal
Fig. 87 - Screw removal
Fig. 88 - Remove the top
•
Remove the side panels (see relative chapter).
•
Loosen the 10 screws along the entire perimeter of the top without removing them (see
•
Remove the stainless steel top (see
13.22
REPLACING THE DOORS
In the event of a replacement, proceed as follows:
Fig. 89 - Undo the screw
Fig. 90 - Remove the door
•
Loosen the door locking screw (see
•
Remove the door by releasing it from the pins (see
).