• After cleaning repeat the operation in reverse order, checking the condition and efficiency of the gasket, and if necessary
replace it.
It is important to sealed the cap othrwise noxiuous fumes will propagate among the room.
6.4
FUME CHAMBER AND FUME PASSAGES CLEANING
Every season (or every 1500 operation hours) the fume chamber and the fume passages cleaning must be executed.
• Remove the side panels of the stove according to the model (see dedicated sections).
• When the stove is cool, remove plate “F” by loosening the two screws (see
).
• To remove plate “G”, you must remove the door (see dedicated section).
• Once the plates have been removed, using the brush provided with the stove, brush the exchanger walls to let dust fall into the
lower compartment.
• Remove the upper deflector (see
), vacuum any ash and clean the internal combustion chamber walls.
• After cleaning, repeat the operation in reverse making sure the gasket is intact and efficient: if necessary, have it replaced by
an authorised technician.
Fig. 83 - Plates removal
Fig. 84 - Cleaning
Once the exchanger cleaning has been finished, you must remove the four screws fixing plates “C” to the structure, remove gasket
“D” and then clean the lower compartment where all ash deposits from previous cleaning operations have accumulated (see
). Remove the screws fixing plate “E” to the structure, clean the fan with the brush and vacuum any residue (see
). If
necessary, replace gasket “D”.
Check the ceramic fibre gasket seal on the stove door. If necessary, order new gaskets from the dealer for replacement or contact
an authorised service centre to perform the entire operation.
Summary of Contents for KRISS3