27
WALL
3
PLUS - TILE
3
PLUS - MOON - LEAN
3
PLUS
PROBLEM
CAUSE
SOLUTION
INTERVENTION
The stove is at its
highest power but
does not heat up.
Ambient tempera-
ture reached.
The stove is at its minimum value. Increase the desired am-
bient temperature.
Stove running and
display showing
"Smoke Overtepe-
rature"
Reached fume
outlet limit tempe-
rature
The stove runs at minimum. NO PROBLEM!
The stove's smoke
duct produces
condensation
Low smoke tempe-
rature
Check that the flue is not clogged.
Increase stove power to minimum (pellet drop and fan revs).
Install condensation collection cup.
Stove running and
display showing
"SERVICE"
Routine main-
tenance alert (it
does not block the
system)
When this flashing message appears upon start-up, it means
that the preset operating hours have elapsed before mainte-
nance. Contact the service centre.
Summary of Contents for LEAN3 PLUS
Page 31: ...NOTE ...