11
SAFETY SYSTEM
11.1
INTRODUCTION
Safety devices are used to prevent and avoid the risk of damages to people, animales and objects.
It is forbidden to execute repearing by no authorized personnel otherwise the warranty and the manufacturer liability fall.
Before of every intervention leave the fire completely extinguish till the cooling and always
disconnect the plug from the electric socket.
11.2
”ALAR NO RETE” ALARM
•
“ALAR NO RETE”: outage during ignition.
•
The stove starts up the switching off phase up by activating the fume fan which for 15 minutes will arrange for
fume remainings expulsion.
•
Reset the error with P4 key.
•
Check the type of glitch as provided by
.
•
Clean the burning pot and start the stove up againg with P4 key.
11.3
”ALAR SOND” ALARM
To the exhaust fan is connected a probe which constantly controls the running temperature.
•
“ALAR SOND”: the probe is damaged or disconnected.
•
The stove starts the switching off phase by activating the fume fan which for about 15 minutes will arrange for
fume remainings expulsion.
•
Reset the error with P4 key.
•
Check the type of glitch as provided by
.
•
Clean the burning pot and start the stove up again with P4 key.
11.4
”ALAR HOT TEMP” ALARM
If the fume probe find a temperature at the exhaust which is higher than 200°C, the display will show “RIS”. At
that point, the combustible flow (pellet) decreases at 1 phase.
This function has the purpose to bring the value back to the preselected data. If for different reasons the
temperature does not decrease but increase, at 215°C the display will show “ALAR HOT TEMP” and the stove
start the switching off phase up.
•
The stove starts the switching off phase up by activating the fume fan which for about 15 minutes will arrange
for fume remainings expulsion.
•
Reset the error with P4 key.
•
Check the type of glitch as provided by
.
•
Clean the burning pot and start the stove up again with P4 key.
11.5
”ALAR NO FIRE” ALARM
•
“ALAR NO FIRE”: the temperature is not sufficient for ignition.
•
The stove starts the switching off phase up by activating the fume fan which for about 15 minutes will arrange
for fume remainings expulsion.
•
Reset the error with P4 key.
•
Check the type of glitch as provided by
.
•
Clean the burning pot and start the stove up again with P4 key.
11.6
”ALAR DEP” ALARM
To the boiler is connected a pressostat which controls the depression.
•
“ALAR DEP”: the pressostat stops the power to the auger.
•
The stove starts the switching off phase up by activating the fume fan which for about 15 minutes will arrange
for fume remainings expulsion.
•
Reset the error with P4 key.
•
Check the type of glitch as provided by
.
•
Clean the burning pot and start the stove up again with P4 key.