PROBLEM SOLVING
Before every testing and/or intervention of the Authorized Technician, the Autorized
Technician personally has the duty to verify that the parameters of the electronic board
meet those of the reference table you own.
In case of doubts regarding the running of the stove please contact ONLY the Autorized
Technician in order to avoid irreparable damages!
PROBLEM
CAUSE
SOLUTION
INTERVENTION
Control display
does not ignite
Stove without power
supply
Check if the plug is put in the socket.
Burned board protection
fuse
Replace the board protection fuse (4A-250V).
Faulty control display
Replace the control display.
Faulty flat cable
Replace tha flat cable.
Faulty electronic board
Replace the mother board.
Pellet does
not reach the
combustion
chamber
Empty tank
Full the hopper.
Auger blocked by a
foreign object (for
example nails)
Clean the auger.
Auger geared motor out
of order
Replace the geared motor.
Check on the display if
there is an active alarm
(“ALAR DEP”, “ALAR SIC”)
Have the stove overhauled.